Inspection Procedure
HINT:
Start the inspection from step 1 when using the intelligent tester and start from step 2 when not using the intelligent tester.
- READ VALUE OF INTELLIGENT TESTER
- Connect the intelligent tester to the DLC3.
- Turn the ignition switch to the ON position.
- Turn the tester ON.
- Enter the following menus: DIAGNOSIS / OBD/MOBD / METER / DATA LIST.
- Check the values by referring to the table below.
METER:
METER SPECIFICATIONItem Measurement Item/Range (Display) Normal Condition Diagnostic Note ODO/TRIP SW ODO/TRIP switch is ON/OFF ON: Switch is pushed
OFF: Switch is not pushed- OK: Switch condition (ON/OFF) can be switched by actual operation.
NG: Go to step 2
OK: REPLACE COMBINATION METER ASSEMBLY
- INSPECT ODO/TRIP SWITCH
- Remove the ODO/TRIP switch.
- Measure the resistance according to the value (s) in the table below.
Standard resistance
RESISTANCE REFERENCE CHARTTester Connection Condition Specified Condition R6-1 (E) - R6-4 (RSET) ODO/TRIP switch is not pressed. 10 kΩ or higher ODO/TRIP switch is pressed. Below 1 Ω
NG: REPLACE LIGHT CONTROL RHEOSTAT
OK: Go to Next Step
- CHECK HARNESS AND CONNECTOR (COMBINATION METER - ODO/TRIP SWITCH)
- Disconnect the C9 and R6 connectors.
- Measure the resistance according to the value (s) in the table below.
Standard resistance
RESISTANCE REFERENCE CHARTTester connection Condition Specified condition C9-13 (RE)-R6-1 (E) Always Below 1 Ω C9-17 (ODO/TRIP SW) - R6-4 (RSET) Always Below 1 Ω C9-13 (RE)-Body ground Always 10 kΩ or higher C9-17 (ODO/TRIP SW) Body ground Always 10 kΩ or higher
NG: REPAIR OR REPLACE HARNESS OR CONNECTOR
OK: REPLACE COMBINATION METER ASSEMBLY