Inspection Procedure
- PERFORM ACTIVE TEST BY INTELLIGENT TESTER
- Connect the intelligent tester to the DLC3.
- Turn the ignition switch to the ON position.
- Turn the tester ON.
- Enter following menus: DIAGNOSIS / OBD/MOBD / METER/ACTIVE TEST.
- Check the values by referring to the table below.
METER:
METER SPECIFICATIONItem Test Details Diagnostic Note FUEL GAUGE EMPTY, 1/2, FULL - OK: Needle indication is normal.
NG: REPLACE COMBINATION METER ASSEMBLY
OK: Go to Next Step
- READ VALUE OF INTELLIGENT TESTER
- Connect the intelligent tester to the DLC3.
- Turn the ignition switch to the ON position.
- Turn the tester ON.
- Enter following menus: DIAGNOSIS / OBD/MOBD / METER / DATA LIST.
- Check the values by referring to the table below.
METER:
METER SPECIFICATIONItem Measurement Item/Range (Display) Normal Condition Diagnostic Note FUEL GAUGE Fuel gauge indicates "F"
Fuel gauge indicates "3/4"
Fuel gauge indicates "1/2"
Fuel gauge indicates "1/4"
Fuel gauge indicates "E"
(Fuel input / Min.: 0, Max.: 255)Fuel gauge indicates "F" 48 (Ω)
Fuel gauge indicates "3/4" 93 (Ω
Fuel gauge indicates "1/2" 148 (Ω)
Fuel gauge indicates "1/4" 188 (Ω)
Fuel gauge indicates "E" 206 (Ω)- OK: Fuel value signal displayed on the tester is almost the same as needle indication.
NG: REPLACE COMBINATION METER ASSEMBLY
OK: Go to Next Step
- INSPECT FUEL SENDER GAUGE ASSEMBLY
- Remove the fuel sender gauge assembly.
- Check that the float position is between E and F and measure the resistance between terminals 2 and 3 of the connector.
- Measure the resistance according to the value (s) in the table below.
OK
RESISTANCE REFERENCEFloat level Resistance (Ω) F 3.0 to 5.0 E 109.0 to 111.0
NG: REPLACE FUEL SENDER GAUGE ASSEMBLY
OK: Go to Next Step
- CHECK HARNESS AND CONNECTOR (COMBINATION METER - FUEL SENDER GAUGE)
- Disconnect the C9 connector and fuel tank wire.
- Measure the resistance according to the value (s) in the table below.
Standard resistance
RESISTANCE REFERENCE CHARTTester Connection Condition Specified Condition C9-19 (FUEL SENDER)-F16-2 Always Below 1 Ω C9-2 (FE) - F16-3 Always Below 1 Ω C9-19 (FUEL SENDER) -Body ground Always 10 kΩ or higher C9-19 (FE)-Body ground Always 10 kΩ or higher
NG: REPAIR OR REPLACE HARNESS OR CONNECTOR
OK: Go to Next Step
- REPLACE COMBINATION METER ASSEMBLY
- Replace the combination meter assembly with a new or normal one.
OK: The operation of the combination meter assembly returns to normal.
NG: REPLACE ECM
OK: END
- Replace the combination meter assembly with a new or normal one.