Home >> Lexus >> 2008 >> IS 250 RWD, Automatic >> Repair and Diagnosis >> External Pages >> Different variant/trim >> Section 1 (A760H Automatic Transaxle) >> Automatic Transmission System >> DTC P2759 Torque Converter Clutch Pressure Control Solenoid Control Circuit Electrical (Shift Solenoid Valve SLU) >> Description

DTC P2759 Torque Converter Clutch Pressure Control Solenoid Control Circuit Electrical (Shift Solenoid Valve SLU): Description

WARNING: This page is about a different variant/trim than selected.

The amount of current flow to the solenoid is controlled by the (*) duty ratio of the ECM output signal. The higher the duty ratio becomes, the higher the lock-up hydraulic pressure becomes during the lock-up operation.

Fig 1: Lock-Up Operation Pressure Graph
G04831069Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002

(*) Duty Ratio

The duty ratio is the ratio of the period of continuity in one cycle. For example, if A is the period of continuity in one cycle, and B is the period of non-continuity, then Duty Ratio = A/(A+B) x 100(%).

DTC DETECTION CONDITION CHART

DTC No. DTC Detection Condition Trouble Area
P2759 Open or short is detected in shift solenoid valve SLU circuit for 1 second or more while driving (1 - trip detection logic).
  • Open or short in shift solenoid valve SLU circuit
  • Shift solenoid valve SLU
  • ECM

Reference (Using an oscilloscope):

Check the waveform between the terminals SLU+ and SLU- of the ECM connector

Fig 2: Identifying Signal Waveform
G04963153Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
WAVEFORM REFERENCE

Terminal SLU+ - SLU-
Tool setting 5 V/DIV., 1 ms./DIV.
Vehicle condition 5th (lock-up) or 6th (lock-up) gear