Home >> Lexus >> 2008 >> IS 250 RWD, Automatic >> Repair and Diagnosis >> External Pages >> Different car >> Section 52 (Automatic Transaxle) >> Automatic Transmission System >> DTC P2759 Torque Converter Clutch Pressure Control Solenoid Control Circuit Electrical (Shift Solenoid Valve SLU) >> Description

DTC P2759 Torque Converter Clutch Pressure Control Solenoid Control Circuit Electrical (Shift Solenoid Valve SLU): Description

WARNING: This page is about a different car, the 2008 Lexus IS 350. However, it is still accessible from the selected car via links, so may be relevant.

The amount of current flow to the solenoid is controlled by the (*) duty ratio of the ECM output signal. The higher the duty ratio becomes, the higher the lock-up hydraulic pressure becomes during the lock-up operation.

Fig 1: Shift Solenoid Valve SLU Pressure Graph
G05824072Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002

(*) Duty Ratio

The duty ratio is the ratio of the period of continuity in one cycle. For example, if A is the period of continuity in one cycle, and B is the period of non-continuity, then Duty Ratio = A/(A+B) x 100(%).

DTC DETECTION CONDITION CHART

DTC No. DTC Detection Condition Trouble Area
P2759 Open or short is detected in shift solenoid valve SLU circuit for 1 second or more while driving (1-trip detection logic).
  • Open or short in shift solenoid valve SLU circuit
  • Shift solenoid valve SLU
  • ECM

Reference (Using an oscilloscope):

Check the waveform between the terminals SLU+ and SLU- of the ECM connector

Fig 2: Identifying Waveform Between Terminals SLU+ And SLU- Of ECM Connector
G05824073Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002

Standard: 

Refer to the illustration above.

WAVEFORM REFERENCE

Terminal SLU+ - SLU-
Tool setting 5V/DIV., 1 ms./DIV.
Vehicle condition 5th (lock-up) or 6th (lock-up) gear