Inspection Procedure
- SYSTEM CHECK
- Confirm the symptoms.
Result
RESULT CHARTResult Proceed to Meter illumination does not change when operate the light control rheostat knob A Dimmer function cannot be canceled B
B: Go to step 6
A: Go to next step
- Confirm the symptoms.
- READ VALUE USING TECHSTREAM (RHEOSTAT VALUE)
- Connect the Techstream to the DLC3
- Turn the engine switch on (IG)
- Turn the Techstream on
- Enter the following menus Body Electrical / Combination Meter / Data List
- Check the values by referring to the table below.
Combination Meter
DIAGNOSTIC NOTETester Display Measurement Item/Range Normal Condition Diagnostic Note Light Control Rheostat Light control rheostat/Min 0%, Max 100% Turn the light control rheostat knob fully counterclockwise (0%) - Turn the light control rheostat knob fully clockwise (100%) OK: The value displayed on the Techstream gradually changes as the actual rheostat operation.
NG: Go to step 4
OK: Go to next step
- READ VALUE USING TECHSTREAM (TAIL CANCEL SW)
- Connect the Techstream to the DLC3
- Turn the engine switch on (IG).
- Turn the Techstream on
- Enter the following menus: Body Electrical / Combination Meter / Data List
- Check the values by referring to the table below
Combination Meter
DIAGNOSTIC NOTETester Display Measurement Item/Range Normal Condition Diagnostic Note Tail Cancel SW Tail cancel switch/OFF or ON OFF Light control rheostat position is except below - ON Turn the light control rheostat knob fully clockwise (Tail cancel switch is ON) - OK: Condition displayed on the Techstream is the same as the actual light control rheostat knob position.
NG: Go to step 7
OK: REPLACE COMBINATION METER (See REMOVAL )
- INSPECT LIGHT CONTROL RHEOSTAT
- Remove the light control rheostat
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
TESTER CONNECTION SPECIFIED CONDITION CHARTTester Connection Condition Specified Condition 1 (E) - 4 (RV) Turn the rheostat knob fully clockwise (MAX) 8 to 12kΩ 1 (E) - 4 (RV) Rheostat knob is between MIN. and MAX. The value changes gradually (Between approx. 0 to 8 kΩ) 1 (E) - 4 (RV) Turn the rheostat knob fully counterclockwise (MIN.) Approx. 0 Ω
NG: REPLACE LIGHT CONTROL RHEOSTAT (See REMOVAL )
OK: Go to next step
- CHECK HARNESS AND CONNECTOR (COMBINATION METER - LIGHT CONTROL RHEOSTAT)
- Disconnect the J34 and J15 connectors
- Measure the resistance according to the value(s) in the table below
Standard Resistance
TESTER CONNECTION SPECIFIED CONDITION CHARTTester Connection Condition Specified Condition J34-14 (ET) - J15-1 (E) Always Below 1 Ω J34-9 (ILL+) - J15-3 (T) Always Below 1 Ω J34-21 (TR) - J15-4 (RV) Always Below 1 Ω J15-1 (E) - Body ground Always 10 kΩ or higher J15-3 (T) - Body ground Always 10 kΩ or higher J15-4 (RV) - Body ground Always 10 kΩ or higher
NG: REPAIR OR REPLACE HARNESS OR CONNECTOR
OK: REPLACE COMBINATION METER (See REMOVAL )
- READ VALUE USING TECHSTREAM (TAIL CANCEL SW)
- Connect the Techstream to the DLC3
- Engine switch on (IG)
- Turn the Techstream on
- Enter the following menus: Body Electrical / Combination Meter / Data List.
- Check the values by referring to the table below.
Combination Meter
DIAGNOSTIC NOTETester Display Measurement Item/Range Normal Condition Diagnostic Note Tail Cancel SW Tail cancel switch/OFF or ON OFF Light control rheostat position is except below - ON Turn the light control rheostat knob fully clockwise (Tail cancel switch is ON) - OK: Condition displayed on the Techstream is the same as the actual light control rheostat position.
NG: Go to step 7
OK: REPLACE COMBINATION METER (See REMOVAL )
- INSPECT LIGHT CONTROL RHEOSTAT
- Remove the light control rheostat
- Measure the resistance according to the value(s) in the table below
Standard Resistance
TESTER CONNECTION SPECIFIED CONDITION CHARTTester Connection Condition Specified Condition 2 (TC) - 3 (T) Light control rheostat knob position is except below Below 1 Ω 2 (TC) - 3 (T) Turn the light control rheostat knob fully clockwise (Tail cancel switch is ON) 10 kΩ or higher
NG: REPLACE LIGHT CONTROL RHEOSTAT (See REMOVAL )
OK: Go to next step
- CHECK HARNESS AND CONNECTOR (COMBINATION METER - LIGHT CONTROL RHEOSTAT)
- Disconnect the J34 and J15 connectors
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
TESTER CONNECTION SPECIFIED CONDITION CHARTTester Connection Condition Specified Condition J34-8 (TC) - J15-2 (TC) Always Below 1 Ω J15-2 (TC) - Body ground Always 10 kΩ or higher J34-9 (ILL+) - J15-3 (T) Always Below 1 Ω J15-3 (T) - Body ground Always 10 kΩ or higher
NG: REPAIR OR REPLACE HARNESS OR CONNECTOR
OK: REPLACE COMBINATION METER (See REMOVAL )