Data List / Active Test

WARNING: This page is about a different car, the 2008 Lexus IS F. However, it is still accessible from the selected car via links, so may be relevant.
  1. READ DATA LIST 

    Use the Techstream to read the Data List allows the values or states of switches, sensors, actuators and other items to be read without removing any parts. This non-intrusive inspection can be very useful because intermittent conditions or signals may be discovered before parts or wiring is disturbed. Reading the Data List information early in troubleshooting is one way to save diagnostic time.

    NOTE: In the table below, the values listed under "Normal Condition" are reference values. Do not depend solely on these reference values when deciding whether a part is faulty or not.
    1. Connect the Techstream to the DLC3.
    2. Turn the engine switch on (IG)
    3. Turn the Techstream on.
    4. Enter the following menus:
      1. for Air Conditioner. Body Electrical / Air Conditioner / Data List.
      2. for Engine and ECT Powertrain / Engine and ECT / Data List.
    5. Check the value(s) by referring to the table below

      Air Conditioner 

      MEASUREMENT ITEM/RANGE AND DIAGNOSTIC NOTE

      Tester Display Measurement Item/Range Normal Condition Diagnostic Note
      Room Temperature Sensor (Room Temp) Room temperature sensor / Min -6 5°C (20 3°F), Max 57 25°C (135 05°F) Actual cabin temperature is displayed -
      Ambient Temp Sensor (Ambi Temp Sens) Ambient temperature sensor / Min -23 3°C (-9 94°F), Max 65 95°C (150 71°F) Actual ambient temperature is displayed -
      Adjusted Ambient Temp (Ambi Temp) Adjusted ambient temperature / Min -30 8°C (-23 44°F), Max 50 8°C (123 44°F) - -
      Evaporator Temp Sensor (Evap Temp) Evaporator temperature sensor / Min -29 7°C (-21 46°F), Max 59 55°C (139 19°F) Actual evaporator temperature is displayed -
      Solar Sensor (D side) (Solar Sens-D) Driver side solar sensor / Min 0, Max 255 Driver side temperature increases as brightness increases -
      Solar Sensor (P side) (Solar Sens-P) Passenger side solar sensor / Min 0, Max 255 Passenger side temperature increases as brightness increases -
      Engine Coolant Temp (Coolant Temp) Engine coolant temperature / Min 1 3°C (34 34°F), Max 90 55°C (194 99°F) Actual engine coolant temperature is displayed while engine is warmed up -
      Set Temperature (D Side) (Set Temp-D) Driver side set temperature /Min 0, Max 255 Driver side set temperature is displayed -
      Set Temperature (P Side) (Set Temp-P) Passenger side set temperature / Min 0, Max 255 Passenger side set temperature is displayed -
      Hand Free Telephone (Hand Free Tel) Hands free telephone / OFF or ON - -
      Blower Motor Speed Level (Blower Level) Blower motor speed level / Min 0, Max 31 Increases in the range between 0 and 31 as the blower motor speed increases -
      Emission Gas Nox Sensor (Nox Gas Sens) Emission gas / Min 0, Max 255 Smog ventilation sensor value increases as gas amount increases -
      Emission Gas Sensor (Emiss Gas Sens) Emission gas / Min 0, Max 255 Smog ventilation sensor value increases as gas amount increases -
      Regulator Pressure Sensor (Reg Press Sens) Regulator pressure sensor / Min -0 45668 MPaG, Max 3 29437 MPaG Actual regulator pressure is displayed -
      Regulator Control Current (Reg Ctrl Currnt) Regulator control current / Min 0 A, Max 255 A - -
      Air Mix Servo Targ Pulse(D) (Air Mix Pulse-D) Driver side air mix servo motor target pulse / Min 0, Max 255 MAX COLD 5 (pulse)
      MAX HOT 104 (pulse)
      -
      Air Mix Servo Targ Pulse(P) (Air Mix Pulse-P) Passenger side air mix servo motor target pulse / Min 0, Max 255 MAX COLD 105 (pulse)
      MAX HOT 6 (pulse)
      -
      Air Outlet Servo Pulse (D) (Air Out Pulse-D) Driver side air outlet servo motor target pulse / Min 0, Max 255 FACE 9 to 17 (pulse)
      B/L 32 to 38 (pulse)
      FOOT 56 to 64 (pulse)
      FOOT/DEF 84 (pulse)
      DEF 97 (pulse)
      -
      Air Inlet Damper Targ Pulse (A/I Damp Targ Pis) Air inlet damper target pulse / Min 0, Max 255 RECIRCULATION 31 (pulse)
      FRESH 7 (pulse)
      -
      Cool Air Bypass Pulse (A/B Damp Pis) Driver side cool air bypass pulse / Min 0, Max 255 CLOSE 50 (pulse)
      OPEN 8 (pulse)
      -
      Number of Trouble Codes (#Codes) Number of trouble codes /Min 0, Max 255 Number of DTCs is displayed -

      Engine and ECT 

      MEASUREMENT ITEM/RANGE AND DIAGNOSTIC NOTE

      Tester Display Measurement Item/Range Normal Condition Diagnostic Note
      A/C Signal (A/C Signal) A/C signal / ON or OFF ON A/C ON
      OFF A/C OFF
      -
  2. PERFORM ACTIVE TEST 

    Use the Techstream to perform Active Tests allows the relay, actuator, and other items to operate without removing any parts This non-intrusive functional inspection can be very useful because intermittent operation may be discovered before parts or wiring is disturbed. Performing Active Test early in troubleshooting is one way to save diagnostic time. Data List information can be display while performing Active Test

    1. Connect the Techstream to the DLC3
    2. Turn the engine switch on (IG)
    3. Turn the Techstream on.
    4. Enter the following menus.
      1. for Air Conditioner: Body Electrical / Air Conditioner / Active Test
      2. for Engine and ECT. Powertrain / Engine and ECT / Active Test
    5. Check the operation by referring to the table below.

      Air Conditioner 

      CONTROL RANGE AND DIAGNOSTIC NOTE

      Tester Display Test Part Control Range Diagnostic Note
      Blower Motor (Blower Motor) Blower motor Min 0, Max 31 -
      Defogger Relay (Rear) (Defogger Rly-R) Defogger relay (Rear) OFF, ON -
      Air Mix Servo Targ Pulse(D) (Air Mix Pulse-D) Driver side air mix servo motor pulse Min 0, Max 255 -
      Air Mix Servo Targ Pulse(P) (Air Mix Pulse-P) Passenger side air mix servo motor pulse Min 0, Max 255 -
      Air Outlet Servo Pulse (D) (Air Out Pulse-D) Driver side air outlet servo motor pulse Min 0, Max 255 -
      Air Inlet Damper Targ Pulse (A/I Damp Targ Pis) Air inlet damper target pulse Min 0, Max 255 -
      Cool Air Bypass Pulse (A/B Damp Pis) Cool air bypass pulse Min 0, Max 255 -