Typical Malfunction Thresholds

WARNING: This page is about a different car, the 2008 Lexus IS F. However, it is still accessible from the selected car via links, so may be relevant.

OFF malfunction 

When one of the following conditions is met OFF malfunction (A), (B), (C), (D) or (E)

OFF malfunction (A) 

TYPICAL MALFUNCTION THRESHOLDS

Turbine speed - Output speed (NT - NO) x 5th gear ratio 400 rpm or more

OFF malfunction (B) 

TYPICAL MALFUNCTION THRESHOLDS

Turbine speed - Output speed (NT - NO) x 6th gear ratio 400 rpm or more

OFF malfunction (C) 

TYPICAL MALFUNCTION THRESHOLDS

Turbine speed - Output speed (NT - NO) x 7th gear ratio 400 rpm or more

OFF malfunction (D) 

TYPICAL MALFUNCTION THRESHOLDS

Turbine speed - Output speed (NT - NO) x 8th gear ratio 400 rpm or more

OFF malfunction (E) 

TYPICAL MALFUNCTION THRESHOLDS

Shift solenoid valve SLT ON malfunction

ON malfunction 

When one of following conditions is met. ON malfunction (A), (B) or (C)

2 detections are necessary per driving cycle

1st detection temporary flag ON

2nd detection. pending fault code ON

ON malfunction (A) 

When either condition below is met Condition (1) or (2)

Condition (1) 

TYPICAL MALFUNCTION THRESHOLDS

Turbine speed / Output speed (NT / NO) 1 141 or more and 1 291 or less (when output speed less than 600 rpm)

Condition (2) 

TYPICAL MALFUNCTION THRESHOLDS

Turbine speed - Output speed (NT - NO) x 5th gear ratio (Actual 5th gear) -50 rpm or more and 50 rpm or less (when output speed 600 rpm or more)

ON malfunction (B) 

When either condition below is met. Condition (1) or (2)

Condition (1) 

TYPICAL MALFUNCTION THRESHOLDS

Turbine speed / Output speed (NT / NO) 0 62 or more and 0 75 or less (when output speed less than 1000 rpm)

Condition (2) 

TYPICAL MALFUNCTION THRESHOLDS

Turbine speed - Output speed (NT - NO) x 8th gear ratio (Actual 8th gear) -50 rpm or more and 50 rpm or less (when output speed 1000 rpm or more)

ON malfunction (C) 

When either condition below is met Condition (1) or (2)

Condition (1) 

TYPICAL MALFUNCTION THRESHOLDS

Turbine speed / Output speed (NT / NO) 0 93 or more and 1 07 or less (when output speed less than 800 rpm)

Condition (2) 

TYPICAL MALFUNCTION THRESHOLDS

Turbine speed - Output speed (NT - NO) x 6th gear ratio (Actual 6th gear) -50 rpm or more and 50 rpm or less (when output speed 800 rpm or more)