Typical Enabling Conditions
WARNING: This page is about a different car, the 2008 Lexus IS 350. However, it is still accessible from the selected car via links, so may be relevant.
TYPICAL ENABLING CONDITIONS
| Monitor runs whenever following DTCs not present | None |
| EVAP key-off monitor runs when all of following conditions met: | - |
| Atmospheric pressure | 70 to 110 kPa-a (525 to 825 mmHg-a) |
| Battery voltage | 10.5 V or more |
| Vehicle speed | Below 2.5 mph (4 km/h) |
| Engine switch | OFF |
| Time after key off | 5 or 7 or 9.5 hours |
| EVAP pressure sensor malfunction (P0450, P0451, P0452 and P0453) | Not detected |
| EVAP canister purge valve | Not operated by scan tool |
| EVAP canister vent valve | Not operated by scan tool |
| EVAP leak detection pump | Not operated by scan tool |
| Both of the following conditions are met before key off: | Conditions 1 and 2 |
| 1. Duration that vehicle has been driven | 5 minutes or more |
| 2. EVAP purge operation | Performed |
| ECT | 4.4 to 35°C (40 to 95°F) |
| IAT | 4.4 to 35°C (40 to 95°F) |
- Key-off monitor sequence 1 to 8
- Atmospheric pressure measurement TYPICAL ENABLING CONDITIONS
Next sequence is run if following condition is met: - Atmospheric pressure change Less than 0.3 kPa (2.25 mmHg) for 1 second - First reference pressure measurement TYPICAL ENABLING CONDITIONS
Next sequence is run if all of the following conditions are met: Conditions 1, 2 and 3 1. EVAP pressure just after reference pressure measurement started -1 kPa (-7.5 mmHg) or less 2. Reference pressure -4.85 to -1.057 kPa (-36.4 to -7.93 mmHg) 3. Reference pressure Saturated within 60 seconds - EVAP canister vent valve stuck close stuck check TYPICAL ENABLING CONDITIONS
Next sequence is run if following condition is met: - EVAP pressure change after vent valve is ON 0.3 kPa (2.25 mmHg) or more - Vacuum introduction TYPICAL ENABLING CONDITIONS
Next sequence is run if following condition is met: - EVAP pressure Saturated within 15 minutes - EVAP canister purge valve close stuck check TYPICAL ENABLING CONDITIONS
Next sequence is run if following condition is met: - EVAP pressure change after purge valve is open 0.3 kPa (2.25 mmHg) or more - Second reference pressure measurement TYPICAL ENABLING CONDITIONS
Next sequence is run if all of the following conditions are met: Conditions 1, 2, 3 and 4 1. EVAP pressure just after reference pressure measurement start -1 kPa (-7.5 mmHg) or less 2. Reference pressure -4.85 to -1.057 kPa (-36.4 to -7.93 mmHg) 3. Reference pressure Saturated within 60 seconds 4. Difference between first reference pressure and second reference pressure Less than 0.7 kPa-g (5.25 mmHg-g) - Leak check TYPICAL ENABLING CONDITIONS
Next sequence is run if following condition is met: - EVAP pressure when vacuum introduction complete Second reference pressure or less - Atmospheric pressure measurement
TYPICAL ENABLING CONDITIONSEVAP monitor is complete if following condition met - Atmospheric pressure difference between sequence 1 and 8 Within 0.3 kPa (2.25 mmHg) - Atmospheric pressure measurement