Typical Malfunction Thresholds
WARNING: This page is about a different car, the 2008 Lexus IS 350. However, it is still accessible from the selected car via links, so may be relevant.
TYPICAL MALFUNCTION THRESHOLDS
| Either of the following conditions is set |
- |
| Difference of TP sensor voltage between VTA1 and VTA2 x 0.8 |
More than 1.6 V |
| Difference of TP sensor voltage between VTA1 and VTA2 x 0.8 |
Less than 0.8 V |