Typical Enabling Conditions
WARNING: This page is about a different car, the 2008 Lexus IS F. However, it is still accessible from the selected car via links, so may be relevant.
TYPICAL ENABLING CONDITIONS CHART
| Monitor runs whenever following DTCs not present | None |
| EVAP key-off monitor runs when all of following conditions met | - |
| Atmospheric pressure | 70 to 110 kPa-a (525 to 825 mmHg-a) |
| Battery voltage | 10 5 V or more |
| Vehicle speed | Below 2 5 mph (4 km/h) |
| Engine switch | off |
| Time after key off | 5 or 7 or 9 5 hours |
| Canister pressure sensor malfunction (P0451, P0452 and P0453) | Not detected |
| Purge VSV | Not operated by scan tool |
| Vent valve | Not operated by scan tool |
| Leak detection pump | Not operated by scan tool |
| Both of following conditions met before key off | Conditions 1 and 2 |
| 1 Duration that vehicle driven | 5 minutes or more |
| 2 EVAP purge operation | Performed |
| Engine coolant temperature | 4 4 to 35°C (40 to 95°F) |
| Intake air temperature | 4 4 to 35°C (40 to 95°F) |
- Key-off monitor sequence 1 to 8
- Atmospheric Pressure Measurement TYPICAL ENABLING CONDITIONS CHART
Next sequence run if following condition set - Atmospheric pressure change Less than 0 3 kPa-g (2 25 mmHg-g) in 1 second - First reference Pressure Measurement TYPICAL ENABLING CONDITIONS CHART
Next sequence run if all of the following conditions set Condition 1, 2 and 3 1 EVAP pressure just after reference pressure measurement started -1 kPa-g (-7 5 mmHg-g) or less 2 Reference pressure -4 85 to -1 057 kPa-g (-36 4 to -7 93 mmHg-g) 3 Reference pressure Saturated within 60 seconds - Vent Valve Stuck Closed Check TYPICAL ENABLING CONDITIONS CHART
Next sequence run if following condition set - EVAP pressure change after vent valve ON (closed) 0 3 kPa-g (2 25 mmHg-g) or more - Vacuum Introduction TYPICAL ENABLING CONDITIONS CHART
Next sequence run if following condition set - EVAP pressure Saturated within 15 minutes - Purge VSV Stuck Closed Check TYPICAL ENABLING CONDITIONS CHART
Next sequence run if following condition set - EVAP pressure change after purge VSV ON (open) 0 3 kPa-g (2 25 mmHg-g) or more - Second Reference Pressure Measurement TYPICAL ENABLING CONDITIONS CHART
Next sequence run if all of following conditions set Condition 1, 2, 3 and 4 1 EVAP pressure just after reference pressure -1 kPa-g (-7 5 mmHg-g) or less 2 Reference pressure -4 85 to -1 057 kPa-g (-36 4 to -7 93 mmHg-g) 3 Reference pressure Saturated within 60 seconds 4 Reference pressure difference between first and second Less than 0 7 kPa-g (5 25 mmHg-g) - Leak Check TYPICAL ENABLING CONDITIONS CHART
Next sequence run if following condition set - EVAP pressure when vacuum introduction complete Second reference pressure or less - Atmospheric Pressure Measurement TYPICAL ENABLING CONDITIONS CHART
EVAP monitor complete if following condition set - Atmospheric pressure difference between sequence 1 and 8 Within 0 3 kPa-g (2 25 mmHg-g)
- Atmospheric Pressure Measurement