Monitor Strategy
MONITOR STRATEGY
| Related DTCs | (Case 1) P1442 AIR VSV stuck close bank 1 (Case 2) P1445 AIR VSV stuck close bank 2 (Case 3) P2441 AIR valve stuck close |
| Required sensors/Components (main) | AIR valve, AIR VSV bank 1, AIR VSV bank 2 |
| Required sensors/Components (sub) | AIR pressure sensor |
| Frequency of operation | Once per driving cycle |
| Duration | Within 20 seconds |
| MIL operation | 2 driving cycles |
| Sequence operation | None |