Home >> Lexus >> 2008 >> GX 470 >> Repair and Diagnosis >> Engine Performance >> Engine Control System >> SFI System >> DTC P1441 Stuck Open in Secondary Air Injection Vacuum Switching Valve Bank 1; DTC P1444 Stuck Open in Secondary Air Injection Vacuum Switching Valve Bank 2; DTC P2440 Secondary Air Injection System Switching Valve Stuck Open Bank 1 >> Typical Malfunction Thresholds

Typical Malfunction Thresholds

P1441 AIR valve bank 1 open stuck: 

TYPICAL MALFUNCTION THRESHOLDS

When both conditions below are met: Condition 1 and 2
1 When one of the following conditions is met Condition (a), (b) or (c)
(a) When both conditions below are met Condition (1)and (2)
(1) When both conditions below are met (during AIR ON). -
Cumulative pressure pulsation 9 kPa or more
AIR pressure 1 kPa or more
(2) When both conditions below are met (during AIR OFF) -
Cumulative pressure pulsation 20 kPa or more
AIR pressure Less than 5 kPa
(b) When both conditions below are met: Condition (1) and (2)
(1) When both conditions below are met (during AIR ON) -
Cumulative pressure pulsation 9 kPa or more
AIR pressure 1 kPa or more
(2) When both conditions below are met (during AIR OFF) -
Cumulative pressure pulsation 30 kPa or more
AIR pressure 5 kPa or more
(c) When both conditions below are met Condition (1)and (2)
(1) When both conditions below are met (during AIR ON) -
Cumulative pressure pulsation 0 kPa or more
AIR pressure Less than 1 kPa
(2) When both conditions below are met (during AIR OFF). -
Cumulative pressure pulsation 20 kPa or more
AIR pressure Less than 5 kPa
2. When one of following conditions is met Condition (a), (b) or (c)
(a) When both conditions below are met Condition (1) or (2)
(1) AIR pressure change at monitor sequence 1 2 5 kPa or more
(2) AIR pressure change at monitor sequence 2 2 5 kPa or more
(b) AIR pressure change at monitor sequence 1 (for AIR valve bank 1) Less than 1 kPa
(c) AIR pressure change at monitor sequence 2 (for AIR valve bank 1) Less than 1 kPa

P1444 AIR valve bank 2 open stuck: 

TYPICAL MALFUNCTION THRESHOLDS

When both conditions below are met: Condition 1 and 2
1. When one of the following conditions is met Condition (a), (b) or (c)
(a) When both conditions below are met Condition (1)and (2)
(1) When both conditions below are met (during AIR ON). -
Cumulative pressure pulsation 9 kPa or more
AIR pressure 1 kPa or more
(2) When both conditions below are met (during AIR OFF). -
Cumulative pressure pulsation 20 kPa or more
AIR pressure Less than 5 kPa
(b) When both conditions below are met Condition (1) and (2)
(1) When both conditions below are met (during AIR ON) -
Cumulative pressure pulsation 9 kPa or more
AIR pressure 1 kPa or more
(2) When both conditions below are met (during AIR OFF) -
Cumulative pressure pulsation 30 kPa or more
AIR pressure 5 kPa or more
(c) When both conditions below are met Condition (1)and (2)
(1) When both conditions below are met (during AIR ON) -
Cumulative pressure pulsation 0 kPa or more
AIR pressure Less than 1 kPa
(2) When both conditions below are met (during AIR OFF) -
Cumulative pressure pulsation 20 kPa or more
AIR pressure Less than 5 kPa
2 When one of following conditions is met Condition (a), (b) or (c)
(a) When both conditions below are met Condition (1)or (2)
(1) AIR pressure change at monitor sequence 1 2 5 kPa or more
(2) AIR pressure change at monitor sequence 2 2 5 kPa or more
(b) AIR pressure change at monitor sequence 1 (for AIR valve bank 2) Less than 1 kPa
(c) AIR pressure change at monitor sequence 2 (for AIR valve bank 2) Less than 1 kPa

P1441 and P1444 AIR valve bank 1 and bank 2 open stuck: 

TYPICAL MALFUNCTION THRESHOLDS

Cumulative pressure pulsation 100 kPa or more

P2440 AIR valve open stuck: 

TYPICAL MALFUNCTION THRESHOLDS

When both of conditions are met (during AIR ON) Condition 1 and 2
1 Cumulative pressure pulsation 9 kPa or more
2 AIR pressure Less than 1 kPa
Cumulative pressure pulsation during monitor sequence 4-2 20 kPa or more

P2440 AIR valve bank 1 and bank 2 open stuck: 

TYPICAL MALFUNCTION THRESHOLDS

Cumulative pressure pulsation 100 kPa or more