LEMON Manuals: Even more car manuals for everyone
Home >> Lexus >> 2007 >> RX 400h AWD >> Repair and Diagnosis >> Hybrid/Electric Powertrain >> Testing and Diagnosis >> Hybrid Vehicle Control (P310) - RX400H - DTC P0AA1-231 Through U0424-537 >> DTC P0ADB-227 Hybrid Battery Positive Contactor Circuit Stuck Open; DTC P0ADC-226 Hybrid Battery Positive Contactor Circuit Stuck Closed >> Inspection Procedure

Inspection Procedure

CAUTION:
  • Before inspecting the high-voltage system, take safety precautions to prevent electrical shocks, such as wearing insulated gloves and removing the service plug grip. After removing the service plug grip, put it in your pocket to prevent other technicians from reconnecting it while you are working on the high-voltage system.
  • After disconnecting the service plug grip, wait for at least 5 minutes before touching any of the high-voltage connectors or terminals.

HINT:

At least 5 minutes is required to discharge the high-voltage capacitor inside the w/ converter inverter assembly.

  1. CHECK HARNESS AND CONNECTOR (HV CONTROL ECU - HV RELAY ASSEMBLY) 
    CAUTION: Be sure to wear insulated gloves.
    1. Turn the ignition switch off and remove the service plug grip. (See HYBRID CONTROL SYSTEM )
      NOTE: Do not put the vehicle into the READY-on state with the service plug grip removed as this may cause a malfunction.
    2. Disconnect the H30 connector from the HV control ECU.
    3. Disconnect the S48 connector from the HV relay assembly.
    4. Measure the voltage according to the value(s) in the table below when the ignition switch is in the ON position.

      HINT:

      If the ignition switch is turned to the ON position with the service plug grip removed, the DTC (P0AOD-350) for the interlock switch system will be output.

      Standard Voltage 

      TESTER CONNECTION AND SPECIFIED CONDITION

      Tester Connection Specified Condition
      CON2 (H30-2) - Body ground Below 1 V
      Fig 1: Disconnecting H30 Connector From HV Control ECU
      G05278739Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
    5. Turn the ignition switch off.
    6. Measure the resistance according to the value(s) in the table below.

      Standard Resistance (Check for open) 

      TESTER CONNECTION AND SPECIFIED CONDITION

      Tester Connection Standard:
      CON2 (H30-2) - CON2 (S48-1) Below 1 Ω

      Standard Resistance (Check for short) 

      TESTER CONNECTION AND SPECIFIED CONDITION

      Tester Connection Specified Condition
      CON2 (H30-2) or CON2 (S48-1) - Body ground 10 kΩ or higher

    NG: REPAIR OR REPLACE HARNESS OR CONNECTOR 

    OK: Go to next step 

  2. INSPECT HV RELAY ASSEMBLY (SMR2) 
    CAUTION: Be sure to wear insulated gloves.
    1. Turn the ignition switch off and remove the service plug grip. (See HYBRID CONTROL SYSTEM )
      NOTE: Do not put the vehicle into the READY-on state with the service plug grip removed as this may cause a malfunction.
    2. Remove the HV relay assembly from the vehicle. (See REMOVAL )
    3. Measure the resistance according to the value(s) in the table below.
      Fig 2: Identifying HV Relay Assembly
      G05278472Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002

      Standard Resistance 

      TESTER CONNECTION AND SPECIFIED CONDITION

      Tester Connection Specified Condition
      S47-1 - S44-1 Below 1 Ω (Apply auxiliary battery voltage between terminals (CON2 (S48-1) and GND (S48-4))
    4. Measure the resistance according to the value(s) in the table below.

      Standard Resistance 

      TESTER CONNECTION AND SPECIFIED CONDITION

      Tester Connection Specified Condition
      CON2 (S48-1) - GND (S48-4) 20 to 60 Ω at -35 to 80°C (-31 to 176°F)

    NG: REPLACE HV RELAY ASSEMBLY 