Inspection Procedure
CAUTION:
- Before inspecting the high-voltage system, take safety precautions to prevent electrical shocks, such as wearing insulated gloves and removing the service plug grip. After removing the service plug grip, put it in your pocket to prevent other technicians from reconnecting it while you are working on the high-voltage system.
- After disconnecting the service plug grip, wait for at least 5 minutes before touching any of the high-voltage connectors or terminals.
HINT:
At least 5 minutes is required to discharge the high-voltage capacitor inside the w/ converter inverter assembly.
- CHECK HV RELAY ASSEMBLY CAUTION: Be sure to wear insulated gloves.
- Turn the ignition switch off and remove the service plug grip. (See
HYBRID CONTROL SYSTEM
)NOTE: Do not put the vehicle into the READY-on state with the service plug grip removed as this may cause a malfunction.
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
TESTER CONNECTION AND SPECIFIED CONDITIONTester Connection Specified Condition S49-1 - S45-1 10 kΩ or higher Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
HINT:
- If a system main relay is stuck closed, inspect The HV relay assembly without removing it from the vehicle, in order to keep the relay closed.
- If P0AA4-232 is output, the HV relay assembly must be replaced. Measuring resistance can determine that this is either a present or past malfunction.
OK: REPLACE HV RELAY ASSEMBLY
OK: REPLACE HV RELAY ASSEMBLY
- Turn the ignition switch off and remove the service plug grip. (See
HYBRID CONTROL SYSTEM
)