Typical Enabling Conditions
TYPICAL ENABLING CONDITIONS
| The monitor will run whenever these DTCs are not present | - |
| EVAP key-off monitor runs when all of the following conditions are met: | - |
| Atmospheric pressure | 70 to 110 kPa (525 to 825 mmHg) |
| Battery voltage | 10.5 V or more |
| Vehicle speed | Below 2.5 mph (4 km/h) |
| Ignition switch | OFF |
| Engine condition | Not running |
| Pressure sensor (built in pump module) malfunction (P0450, P0451, P0452 and/or P0453) | Not detected |
| Purge VSV | Not operated by scan tool |
| Vent valve | Not operated by scan tool |
| Leak detection pump | Not operated by scan tool |
| Both of the following conditions are met before ignition switch OFF | Conditions 1 and 2 |
| 1. Duration that vehicle is being driven | 5 minutes or more |
| 2. Purge flow | Executed |
| ECT | 4.4 to 35°C (40 to 95°F) |
| IAT | 4.4 to 35°C (40 to 95°F) |
| Time after engine stopped | 5 hours |
Example of restart time
TYPICAL ENABLING CONDITIONS
| First time | 7 hours |
| Second time | 9 hours and 30 minutes |
Key-off monitor sequence 1 to 15
- Atmospheric pressure measurement KEY-OFF MONITOR REFERENCE
Next sequence is run if the following condition is met: - Atmospheric pressure change for 10 sec. Less than 0.3 kPa (2.25 mmHg) for 1 second - First reference pressure measurement KEY-OFF MONITOR REFERENCE
Next sequence is run if all of the following conditions are met: Conditions 1, 2 and 3 1. EVAP pressure when 1.9 seconds after reference pressure measurement -1 kPa (-7.5 mmHg) or less 2. Reference pressure -4.85 to -1.057 kPa (-36.38 to -7.93 mmHg) 3. Reference pressure Saturated within 1 minute - Vent valve stuck closed check KEY-OFF MONITOR REFERENCE
Next sequence is run if the following condition is met: - EVAP change for 10 seconds after vent valve ON (Closed) 0.3 kPa (2.25 mmHg) or more - Vacuum introduction for canister KEY-OFF MONITOR REFERENCE
Next sequence is run if both of the following conditions are met: Conditions 1 and 2 1. Vacuum introduction time 15 minutes or less 2. EVAP pressure Saturated - EVAP VSV stuck closed check KEY-OFF MONITOR REFERENCE
Next sequence is run if the following condition is met: - EVAP pressure change for 10 seconds after EVAP VSV ON (Open). 0.3 kPa (2.25 mmHg) or more - Second reference pressure measurement KEY-OFF MONITOR REFERENCE
Next sequence is run if all of the following conditions are met: Conditions 1, 2, 3 and 4 1. EVAP pressure when 1.9 sec. after reference pressure measurement began -1 kPa (-7.5 mmHg) or less 2. Reference pressure -4.85 to -1.057 kPa (-36.4 to -7.93 mmHg) 3. Reference pressure Saturated within 1 minute 4. Reference pressure difference between the first and second 0.7 kPa (5.25 mmHg) or less - Canister leak check KEY-OFF MONITOR REFERENCE
Next sequence is run if the following condition is met: - EVAP pressure when vacuum introduction was complete Less than second reference pressure - Fuel vapor-containment valve (FVCV stuck closed check) KEY-OFF MONITOR REFERENCE
Sequence 14 is run if all of the following conditions are met: Conditions 1 and 2 1. FTP when EVAP monitor started -2 kPa (-15 mmHg) or less, or 3 kPa (22.5 mmHg) or more 2. FTP change while FVCV and vent valve are open 0.5 kPa (3.75 mmHg) or more - Vacuum introduction for fuel tank KEY-OFF MONITOR REFERENCE
Next sequence is run if both of the following conditions are met: Conditions 1 and 2 1. FTP when EVAP monitor started -2 to 3 kPa (-15 to 22.5 mmHg) 2. Vacuum introduction time 15 minutes or less - FVCV stuck closed check KEY-OFF MONITOR REFERENCE
Next sequence is run if the following condition is met: - FTP change when vacuum introduction for fuel tank 0.5 kPa (3.75 mmHg) - FTP sensor stuck check KEY-OFF MONITOR REFERENCE
Next sequence is run if the following condition is met: - FTP change when FVCV closed 0.35 kPa (2.6 mmHg) or less - Third reference pressure measurement KEY-OFF MONITOR REFERENCE
Next sequence is run if all of the following conditions are met: Conditions 1,2, 3, and 4 1. FTP when 1.9 seconds after reference pressure measurement began -1 kPa (-7.5 mmHg) or more 2. Reference pressure -4.85 to -1.057 kPa (-36.4 to -7.93 mmHg) 3. Reference pressure Saturated 4. Reference pressure difference between second and third Less than 0.7 kPa (5.25 mmHg) - Fuel tank leak check KEY-OFF MONITOR REFERENCE
Sequence is run if the following condition is met: - FTP when vacuum introduction for fuel tank was complete Less than third reference pressure - FTP sensor stuck check KEY-OFF MONITOR REFERENCE
Next sequence is run if the following condition is met: - FTP change while FVCV and vent valve are open Less than 0.3 kPa (2.25 mmHg) - Atmospheric pressure measurement KEY-OFF MONITOR REFERENCE
Monitor is complete if the following condition is met: - Atmospheric pressure difference between sequence 1 and 8 0.35 kPa (2.6 mmHg) or less