Monitor Strategy
MONITOR STRATEGY
| Related DTCs | P0351: Igniter (cylinder 1) malfunction P0352: Igniter (cylinder 2) malfunction P0353: Igniter (cylinder 3) malfunction P0354: Igniter (cylinder 4) malfunction P0355: Igniter (cylinder 5) malfunction P0356: Igniter (cylinder 6) malfunction |
| Required Sensors/Components (Main) | Igniter (Cylinder 1 to 6) |
| Frequency of Operation | Continuous |
| Duration | 0.256 seconds and 4 sparks |
| MIL Operation | Immediate |
| Sequence of Operation | None |