Typical Enabling Conditions
TYPICAL ENABLING CONDITIONS
| The monitor will run whenever these DTCs are not present | None |
| Either of the following conditions met | Condition 1 or 2 |
| 1. All of the following conditions are met: | Condition (a) and (b) |
| (a) Engine RPM | 500 RPM or less |
| (b) Battery voltage | 6 V or more |
| 2. All of the following conditions are met: | Condition (c) and (d) |
| (c) Engine RPM | More than 500 RPM |
| (d) Battery voltage | 10 V or more |