LEMON Manuals: Even more car manuals for everyone
Home >> Lexus >> 2007 >> LX 470 >> Repair and Diagnosis >> Engine Performance >> Engine Control System (2UZ-FE) >> SFI System >> DTC P1442 Stuck Close in Secondary Air Injection Vacuum Switching Valve Bank 1; DTC P1445 Stuck Close in Secondary Air Injection Vacuum Switching Valve Bank 2; DTC P2441 Secondary Air Injection System Switching Valve Stuck Close Bank 1 >> Typical Malfunction Thresholds

Typical Malfunction Thresholds

P1442 AIR valve bank 1 close stuck 

TYPICAL MALFUNCTION THRESHOLDS

When both conditions below are met: Condition 1 and 2
1. When one of following conditions is met: Condition (a), (b), (c) or (d)
(a) When both conditions below are met: Condition (1)and (2)
(1) When both conditions below are met (during AIR ON): -
  • Cumulative pressure pulsation
Less than 15 kPa
  • AIR pressure
1 kPa or more
(2) When both conditions below are met (during AIR OFF): -
  • Cumulative pressure pulsation
Less than 30 kPa
  • AIR pressure
5 kPa or more
(b) When both conditions below are met: Condition (1)and (2)
(1) When both conditions below are met (during AIR ON): -
  • Cumulative pressure pulsation
Less than 15 kPa
  • AIR pressure
1 kPa or more
(2) When both conditions below are met (during AIR OFF): -
  • Cumulative pressure pulsation
Less than 20 kPa
  • AIR pressure
Less than 5 kPa
(c) When both conditions below are met: Condition (1)and (2)
(1) When both conditions below are met (during AIR ON): -
  • Cumulative pressure pulsation
Less than 15 kPa
  • AIR pressure
Less than 1 kPa
(2) When both conditions below are met (during AIR OFF): -
  • Cumulative pressure pulsation
Less than 30 kPa
  • AIR pressure
5 kPa or more
(d) When both conditions below are met: Condition (1)or(2)
(1) When both conditions below are met (during AIR ON): -
  • Cumulative pressure pulsation
Less than 15 kPa
  • AIR pressure
Less than 1 kPa
(2) When both conditions below are met (during AIR OFF): -
  • Cumulative pressure pulsation
Less than 20 kPa
  • AIR pressure
Less than 5 kPa
2. When one of following conditions is met: Condition (a), (b) or (c)
(a) AIR pressure change at monitor sequence 1 (for AIR valve bank 1) Less than 1 kPa
(b) AIR pressure change at monitor sequence 2 (for AIR valve bank 1) Less than 1 kPa
(c) Cumulative pressure pulsation during monitor sequence 4-1 (for AIR valve bank 1) Less than 15 kPa

P1445 AIR valve bank 2 close stuck 

TYPICAL MALFUNCTION THRESHOLDS

When both conditions below are met: Condition 1 and 2
1. When one of following conditions is met: Condition (a), (b), (c) or (d)
(a) When both conditions below are met: Condition (1) and (2)
(1) When both conditions below are met (during AIR ON): -
  • Cumulative pressure pulsation
Less than 15 kPa
  • AIR pressure
1 kPa or more
(2) When both conditions below are met (during AIR OFF): -
  • Cumulative pressure pulsation
Less than 30 kPa
  • AIR pressure
5 kPa or more
(b) When both conditions below are met: Condition (1) and (2)
(1) When both conditions below are met (during AIR ON): -
  • Cumulative pressure pulsation
Less than 15 kPa
  • AIR pressure
1 kPa or more
(2) When both conditions below are met: -
  • Cumulative pressure pulsation
Less than 20 kPa
  • AIR pressure
Less than 5 kPa
(c) When both conditions below are met: Condition (1)and (2)
(1) When both conditions below are met (during AIR ON): -
  • Cumulative pressure pulsation
Less than 15 kPa
  • AIR pressure
Less than 1 kPa
(2) When both conditions below are met (during AIR OFF): -
  • Cumulative pressure pulsation
Less than 30 kPa
  • AIR pressure
5 kPa or more
(d) When both conditions below are met: Condition (1) or (2)
(1) When both conditions below are met (during AIR ON): -
  • Cumulative pressure pulsation
Less than 15 kPa
  • AIR pressure
Less than 1 kPa
(2) When both conditions below are met (during AIR OFF): -
  • Cumulative pressure pulsation
Less than 20 kPa
  • AIR pressure
Less than 5 kPa
2. When one of following conditions is met: Condition (a), (b) or (c)
(a) AIR pressure change at monitor sequence 1 (for AIR valve bank2) Less than 1 kPa
(b) AIR pressure change at monitor sequence 2 (for AIR valve bank2) Less than 1 kPa
(c) Cumulative pressure pulsation during monitor sequence 4-1 (for AIR valve bank 2) Less than 15 kPa

P2441 AIR valve close stuck 

TYPICAL MALFUNCTION THRESHOLDS

When both conditions below are met (during AIR ON) Condition 1 and 2
1. Cumulative pressure pulsation Less than 15 kPa
2. AIR pressure 1 kPa or more