LEMON Manuals: Even more car manuals for everyone
Home >> Lexus >> 2007 >> LX 470 >> Repair and Diagnosis >> Engine Performance >> Engine Control System (2UZ-FE) >> SFI System >> DTC P1442 Stuck Close in Secondary Air Injection Vacuum Switching Valve Bank 1; DTC P1445 Stuck Close in Secondary Air Injection Vacuum Switching Valve Bank 2; DTC P2441 Secondary Air Injection System Switching Valve Stuck Close Bank 1 >> Typical Enabling Conditions

Typical Enabling Conditions

TYPICAL ENABLING CONDITIONS

This monitor runs whenever these DTCs are not present
  • P0010 - P0022: VVT system
  • P0031 - P0052: Front A/F sensor heater
  • P0100 - P0103: MAF sensor
  • P0110 - P0113: IAT sensor
  • P0115 - P0118: ECT sensor
  • P0120 - P0223, P2135: TP sensor
  • P0125: Closed loop
  • P0171, P0172: Fuel trim
  • P0300 - P0308: Misfire
  • P0327 - P0333: Knock sensor
  • P0335: CKP sensor
  • P0340 - P0346: VVT sensor
  • P0351 - P0358: Igniter
  • P0450 - P0453: EVAP pressure sensor
  • P0455 - P0456: EVAP system
  • P0500: VSS
  • P2196, P2198: A/F sensor (rationality)
  • P2237, P2240: A/F sensor (open)
  • P2430 - P2433: AIR pressure sensor
  • P2A00, P2A03: A/F sensor (slow response)
Atmospheric pressure 45 kPa (420 mmHg) or more
Battery voltage 11.5 V or higher
AIR monitor runs in accordance with the monitor sequence 1 to 5 -
Monitor Sequence 1
Idle ON
AIR status ON
AIR pump ON
AIR valve ON
Either of following conditions 1 or 2 is met -
1. Both of the following conditions are met -
  • AIR valve bank 1
ON
  • AIR valve bank 2
OFF
2. Both of the following conditions are met -
  • AIR valve bank 1
OFF
  • AIR valve bank 2
ON
Monitor Sequence 2
Idle ON
AIR valve ON
AIR VSV bank 1 ON
AIR VSV bank 2 ON
Monitor Sequence 3
Engine RPM Less than 3,750 rpm
AIR status ON
AIR pump ON
AIR valve ON
AIR valve bank 1 ON
AIR valve bank 2 ON
Monitor Sequence 4-1
Runs when AIR pressure did not change at monitor sequence 2
Engine RPM Less than 3,750 rpm
AIR status OFF
AIR pump ON
AIR valve ON
Either of following conditions 1 or 2 is met -
1. Both of the following conditions are met -
  • AIR valve bank 1
ON
  • AIR valve bank 2
OFF
2. Both of the following conditions are met -
  • AIR valve bank 1
OFF
  • AIR valve bank 2
ON
Monitor Sequence 4-2
Engine RPM Less than 3,750 rpm
AIR status OFF
AIR pump OFF
AIR valve OFF
AIR VSV bank 1 OFF
AIR VSV bank 2 OFF
Monitor Sequence 5
Engine RPM Less than 3,750 rpm
AIR status OFF
AIR pump OFF
AIR valve ON
AIR VSV bank 1 OFF
AIR VSV bank 2 OFF