Typical Malfunction Thresholds
[P0746 and P0771: OFF malfunction]
All of the following conditions are met: OFF malfunction (A), (B) and (C)
2 detections are necessary per driving cycle
1st detection; temporary flag ON
2nd detection; pending fault code ON
OFF malfunction (A)
TYPICAL MALFUNCTION THRESHOLDS TABLE
| Turbine speed/Output speed | 0.93 to 1.07 |
OFF malfunction (B)
TYPICAL MALFUNCTION THRESHOLDS TABLE
| Turbine speed/Output speed | Not change as follow 0.93 to 1.07 ↓ 0.65 to 0.79 |
OFF malfunction (C)
TYPICAL MALFUNCTION THRESHOLDS TABLE
| Output record from ECM for 4th → 5th upshifting | Recorded |
[P0771: ON malfunction]
2 detections are necessary per driving cycle
1st detection; temporary flag ON
2nd detection; pending fault code ON
ON malfunction
TYPICAL MALFUNCTION THRESHOLDS TABLE
| Turbine speed - Output speed x 1st gear ratio (NT - NO x 1st gear ratio) | 150 rpm or more |