DTC Summary
DTC SUMMARY
| DTC No. | Monitoring Items | Malfunction Detection Conditions | Trouble Areas | Detection Timing | Detection Logic | ||
|---|---|---|---|---|---|---|---|
| P2419 | Vent valve stuck closed | Vacuum pump creates negative pressure through 0.02 inch orifice and EVAP system pressure measured to determine leak pressure standard. If system pressure higher than -1.06 kPa (-7.95 mmHg)(1) 4 seconds after vacuum pump turned ON, ECM determines that vent valve stuck closed. |
|
Ignition switch OFF | 2 trip | ||
| P2420 | Vent valve stuck open (vent) | Vacuum pump creates negative pressure through 0.02 inch orifice and EVAP system pressure measured to determine leak pressure standard. 0.02 inch leak pressure standard is measured at the start and at the end of the leak check. If system pressure does not increase by more than 0.3 kPa (2.25 mmHg) within 10 seconds when vent valve turned ON, ECM determines that vent valve stuck closed. |
|
Ignition switch OFF | 2 trip | ||
|
|||||||
HINT:
The vent value is built into the pump module.