Home >> Lexus >> 2007 >> GX 470 >> Repair and Diagnosis >> Engine Performance >> System >> Engine Control System - DTC P0657 - P2A03 >> DTC P1441, P1444, P2440: Stuck Open in Secondary Air Injection Vacuum Switching Valve Bank 1; Stuck Open in Secondary Air Injection Vacuum Switching Valve Bank 2; Secondary Air Injection System Switching Valve Stuck Open Bank1 >> Typical Malfunction Thresholds

Typical Malfunction Thresholds

P1441 AIR valve bank 1 open stuck: 

TYPICAL MALFUNCTION THRESHOLDS

When both conditions below are met: Condition 1 and 2
1. When one of the following conditions is met: Condition (a), (b) or (c)
(a) When both conditions below are met: Condition (1) and (2)
(1) When both conditions below are met (during AIR ON): -
Cumulative pressure pulsation 15 kPa or more
AIR pressure 1 kPa or more
(2) When both conditions below are met (during AIR OFF): -
Cumulative pressure pulsation 20 kPa or more
AIR pressure Less than 5 kPa
(b) When both conditions below are met: Condition (1) and (2)
(1) When both conditions below are met (during AIR ON): -
Cumulative pressure pulsation 15 kPa or more
AIR pressure 1 kPa or more
(2) When both conditions below are met (during AIR OFF): -
Cumulative pressure pulsation 30 kPa or more
AIR pressure 5 kPa or more
(c) When both conditions below are met: Condition (1) and (2)
(1) When both conditions below are met (during AIR ON): -
Cumulative pressure pulsation 15 kPa or more
AIR pressure Less than 1 kPa
(2) When both conditions below are met (during AIR OFF): -
Cumulative pressure pulsation 20 kPa or more
AIR pressure Less than 5 kPa
2. When one of following conditions is met: Condition (a), (b) or (c)
(a) When both conditions below are met: Condition (1) or (2)
(1) AIR pressure change at monitor sequence 1 2.5 kPa or more
(2) AIR pressure change at monitor sequence 2 2.5 kPa or more
(b) AIR pressure change at monitor sequence 1 (for AIR valve bank 1) Less than 1 kPa
(c) AIR pressure change at monitor sequence 2 (for AIR valve bank 1) Less than 1 kPa

P1444 AIR valve bank 2 open stuck: 

TYPICAL MALFUNCTION THRESHOLDS

When both conditions below are met: Condition 1 and 2
1. When one of the following conditions is met: Condition (a), (b) or (c)
(a) When both conditions below are met: Condition (1) and (2)
(1) When both conditions below are met (during AIR ON): -
Cumulative pressure pulsation 15 kPa or more
AIR pressure 1 kPa or wore
(2) When both conditions below are met (during AIR OFF): -
Cumulative pressure pulsation 20 kPa or more
AIR pressure Less than 5 kPa
(b) When both conditions below are met: Condition (1) and (2)
(1) When both conditions below are met (during AIR ON): -
Cumulative pressure pulsation 15 kPa or more
AIR pressure 1 kPa or more
(2) When both conditions below are met (during AIR OFF): -
Cumulative pressure pulsation 30 kPa or more
AIR pressure 5 kPa or more
(c) When both conditions below are met: Condition (1) and (2)
(1) When both conditions below are met (during AIR ON): -
Cumulative pressure pulsation 15 kPa or more
AIR pressure Less than 1 kPa
(2) When both conditions below are met (during AIR OFF): -
Cumulative pressure pulsation 20 kPa or more
AIR pressure Less than 5 kPa
2. When one of following conditions is met: Condition (a), (b) or (c)
(a) When both conditions below are met: Condition (1) or (2)
(1) AIR pressure change at monitor sequence 1 2.5 kPa or more
(2) AIR pressure change at monitor sequence 2 2.5 kPa or more
(b) AIR pressure change at monitor sequence 1 (for AIR valve bank 2) Less than 1 kPa
(c) AIR pressure change at monitor sequence 2 (for AIR valve bank 2) Less than 1 kPa

P1441 and P1444 AIR valve bank 1 and bank 2 open stuck: 

TYPICAL MALFUNCTION THRESHOLDS

Cumulative pressure pulsation 100 kPa or more

P2440 AIR valve open stuck: 

TYPICAL MALFUNCTION THRESHOLDS

When both of conditions are met (during AIR ON): Condition 1 and 2
1. Cumulative pressure pulsation 15 kPa or more
2. AIR pressure Less than 1 kPa
Cumulative pressure pulsation during monitor sequence 4-2 20 kPa or more

P2440 AIR valve bank 1 and bank 2 open stuck: 

TYPICAL MALFUNCTION THRESHOLDS

Cumulative pressure pulsation 100 kPa or more