  1. INSTALL HEATED OXYGEN SENSOR (for Bank 1) 
    1. Using SST, install the sensor.

      SST 09224-00010 

      Torque: 40 N*m (408 kgf*cm, 30 ft.*lbf) for use with SST 

      44 N*m (449 kgf*cm, 32 ft.*lbf) for use without SST 

      HINT:

      Use a torque wrench with a fulcrum length of 300 mm (11.81 in.).

    2. Pass the sensor connector through the floor panel and into the cabin, and install the grommet.
    3. Connect the sensor connector.
    Fig 1: Installing Heated Oxygen Sensor (For Bank 1)
    G05287367Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
    Fig 2: Identifying Grommet
    G05287363Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
  2. INSTALL HEATED OXYGEN SENSOR (for Bank 2) 
    1. Using SST, install the sensor.

      SST 09224-00010 

      Torque: 40 N*m (408 kgf*cm, 30 ft.*lbf) for use with SST 

      44 N*m (449 kgf*cm, 32 ft.*lbf) for use without ST 

      HINT:

      Use a torque wrench with a fulcrum length of 300 mm (11.81 in.).

      Fig 3: Installing Heated Oxygen Sensor (For Bank 2)
      G05287369Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
    2. Pass the sensor connector through the floor panel and into the cabin, and install the grommet.
    3. Connect the sensor connector.
      Fig 4: Connecting Sensor Connector
      G05287365Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
  3. INSTALL INSTRUMENT PANEL FINISH PANEL END LH (See  INSTALLATION  ) 
  4. INSTALL INSTRUMENT PANEL FINISH PANEL END RH (See  INSTALLATION  ) 
  5. INSTALL FRONT ASH RECEPTACLE ASSEMBLY (See  INSTALLATION  ) 
  6. INSTALL FRONT CONSOLE UPPER PANEL GARNISH (See  INSTALLATION  ) 
  7. CONNECT CABLE TO NEGATIVE BATTERY TERMINAL 
  8. PERFORM INITIALIZATION 
    1. Perform initialization (see  INITIALIZATION  ). 
      NOTE: Certain systems need to be initialized after disconnecting and reconnecting the cable from the negative (-) battery terminal.