Inspection Procedure
- READ VALUE OF INTELLIGENT TESTER
- Operate the intelligent tester according to the steps on the display and select "DATA LIST".
METER:
METERItem Measurement Item/Range (Display) Normal Condition Diagnostic Note RHEOSTAT VOL Light control rheostat / Min.: 0, Max.: 255 Light control rheostat switch is Dark (0) -> Bright (255) - OK: Light brightness can be changed within the specified range by actual operation.
NG : Go to step 2
OK : REPLACE COMBINATION METER ASSEMBLY
- Operate the intelligent tester according to the steps on the display and select "DATA LIST".
- INSPECT LIGHT CONTROL RHEOSTAT
- Remove the light control rheostat with connector still connected.
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
LIGHT CONTROL RHEOSTATTester Connection Condition Specified Condition R6-1 (E) - R6-7 (RV) Rheostat knob is in the MAX. position 8 to 12 kΩ R6-1 (E) - R6-7 (RV) Rheostat knob is in the MIN. position. Approx. 0 Ω
NG : REPLACE LIGHT CONTROL RHEOSTAT
OK : GO TO NEXT STEP
- CHECK HARNESS AND CONNECTOR (BETWEEN COMBINATION METER AND LIGHT CONTROL RHEOSTAT)
- Disconnect the C9 and R6 connectors.
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
COMBINATION METER AND LIGHT CONTROL RHEOSTATTester Connection Condition Specified Condition C9-13 (RE) - R6-1 (E) Always Below 1 Ω C9-14 (TR) - R6-7 (RV) Always Below 1 Ω R6-7 (RV) - Body ground Always 10 kΩ or higher R6-1 (E) - Body ground Always Below 1 Ω
NG : REPAIR OR REPLACE HARNESS OR CONNECTOR
OK : REPLACE COMBINATION METER ASSEMBLY