Typical Malfunction Thresholds
WARNING: This page is about a different variant/trim than selected.
P0976:
Range check (Low resistance)
P0976 TYPICAL MALFUNCTION THRESHOLDS TABLE
| Shift solenoid valve S2 resistance |
8 ohms or less |
P0977:
Range check (High resistance)
P0977 TYPICAL MALFUNCTION THRESHOLDS TABLE
| Shift solenoid valve S2 resistance |
100 k ohms or more |