Typical Malfunction Thresholds
WARNING: This page is about a different variant/trim than selected.
Both of the following conditions are met: Condition (A), and Condition (B), (C) or (D)
Malfunction (A)
TYPICAL MALFUNCTION THRESHOLDS TABLE - MALFUNCTION (A)
| Turbine speed/Output speed (NT/NO) | 3.40 or more, and 7.50 or less (This means actual gear is 1st) |
Malfunction (B)
TYPICAL MALFUNCTION THRESHOLDS TABLE - MALFUNCTION (B)
| Turbine speed/Output speed (NT/NO) | 1.28 or more, and 1.53 or less (This means actual gear is 3rd) |
Malfunction (C)
TYPICAL MALFUNCTION THRESHOLDS TABLE - MALFUNCTION (C)
| Turbine speed - Output speed x 4th gear ratio (NT - NO x 4th gear ratio) | 1,000 rpm or more |
Malfunction (D)
TYPICAL MALFUNCTION THRESHOLDS TABLE - MALFUNCTION (D)
| Turbine speed - Output speed x 5th gear ratio (NT - NO x 5th gear ratio) | 1,000 rpm or more |