Typical Malfunction Thresholds
WARNING: This page is about a different variant/trim than selected.
[OFF malfunction]
Both of the following conditions are met: OFF malfunctions (A) and (B)
OFF malfunction (A)
TYPICAL MALFUNCTION THRESHOLDS TABLE - OFF MALFUNCTION (A)
| Turbine speed/Output speed (NT/NO) | 1.28 or more, and 1.53 or less (This means actual gear is 3rd) |
OFF malfunction (B)
TYPICAL MALFUNCTION THRESHOLDS TABLE - OFF MALFUNCTION (B)
| Turbine speed/Output speed (NT/NO) | 0.65 or more, and 0.79 or less (This means actual gear is 5th) |
[ON malfunction]
Both of the following conditions are met: ON malfunctions (A) and (B)
ON malfunction (A)
TYPICAL MALFUNCTION THRESHOLDS TABLE - ON MALFUNCTION (A)
| Turbine speed/Output speed (NT/NO) | 0.51 or more, and 0.65 or less (This means actual gear is 6th) |
ON malfunction (B)
TYPICAL MALFUNCTION THRESHOLDS TABLE - OFF MALFUNCTION (B)
| Turbine speed/Output speed (NT/NO) | 0.51 or more, and 0.65 or less (This means actual gear is 6th) |