Typical Malfunction Thresholds
WARNING: This page is about a different variant/trim than selected.
[OFF malfunction]
Both of the following conditions are met:
OFF malfunction (A)
OFF malfunction (B), (C) or (D)
OFF malfunction (A)
TYPICAL MALFUNCTION THRESHOLDS TABLE - OFF MALFUNCTION (A)
| Turbine speed/Output speed (NT/NO) | 0.65 or more, and 0.79 or less (This means actual gear is 5th) |
OFF malfunction (B)
TYPICAL MALFUNCTION THRESHOLDS TABLE - OFF MALFUNCTION (B)
| Turbine speed/Output speed (NT/NO) | 3.40 or more, and 7.50 or less (This means actual gear is 1st) |
OFF malfunction (C)
TYPICAL MALFUNCTION THRESHOLDS TABLE - OFF MALFUNCTION (C)
| Turbine speed-Output speed x 5th gear ratio (NT-NO x 5th gear ratio) | 1,000 rpm or more |
OFF malfunction (D)
TYPICAL MALFUNCTION THRESHOLDS TABLE - OFF MALFUNCTION (D)
| Turbine speed-Output speed x 6th gear ratio (NT-NO x 6th gear ratio) | 1,000 rpm or more |
[ON malfunction]
Both of the following conditions are met: ON malfunction (A) and (B)
2 detections are necessary per driving cycle:
1st detection; temporary flag ON
2nd detection; pending fault code ON
ON malfunction (A)
TYPICAL MALFUNCTION THRESHOLDS TABLE - ON MALFUNCTION (A)
| Turbine speed/Output speed (NT/NO) | 1.91 or more, and 2.50 or less (This means actual gear is 2nd) |
ON malfunction (B)
TYPICAL MALFUNCTION THRESHOLDS TABLE - ON MALFUNCTION (B)
| Turbine speed/Output speed (NT/NO) | 0.65 or more, and 0.79 or less (This means actual gear is 5th) |