DTC P0748 Pressure Control Solenoid "A" Electrical (Shift Solenoid Valve SL1): Description
WARNING: This page is about a different variant/trim than selected.
Shifting from 1st to 6th is performed in combination with "ON" and "OFF" operation of the shift solenoid valves SL1, SL2, S1, S2, S3, S4 and SR which is controlled by the ECM. If an open or short circuit occurs in either of the shift solenoid valves, the ECM controls the remaining normal shift solenoid valve to allow the vehicle to be operated smoothly (See FAIL-SAFE TABLE ).
DTC DETECTING CONDITION - TROUBLE AREA
| DTC No. | DTC Detection Condition | Trouble Area |
|---|---|---|
| P0748 | The ECM checks for an open or short in the shift solenoid valve SL1 circuit while driving and shifting between 4th and 5th gear. (1-trip detection logic)
|
|
Reference (Using an oscilloscope):
Check the waveform between the terminals SL1+ and SL1- of the ECM connector
Standard:
Refer to the illustration.
SL1+ AND SL1-
| Terminal | SL1+ - SL1- |
|---|---|
| Tool setting | 5 V/DIV., 1 ms./DIV. |
| Vehicle condition | 5th or 6th gear |