LEMON Manuals: Even more car manuals for everyone
Home >> Lexus >> 2006 >> IS 250 RWD, Standard >> Repair and Diagnosis >> External Pages >> Different car >> Section 9 (Cooling (2GR-FSE)) >> Cooling Fan Motor >> On-Vehicle Inspection

On-Vehicle Inspection

WARNING: This page is about a different car, the 2006 Lexus IS 350. However, it is still accessible from the selected car via links, so may be relevant.
  1. CHECK NO. 1 COOLING FAN MOTOR 
    1. Check that the motor turns smoothly when the battery is connected to the fan motor connector.
    2. Measure the current while the motor is turning.
      Fig 1: Identifying No 1 Cooling Fan Motor Connector
      G04057776Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002

      Standard current: 5.3 to 8.3 A at 20°C (68°F) 

      If the result is not as specified, replace the No.1 cooling fan motor.

  2. CHECK NO. 2 COOLING FAN MOTOR 
    1. Check that the motor turns smoothly when the battery is connected to the fan motor connector.
    2. Measure the current while the motor is turning.

      Standard current: 5.3 to 8.3 A at 20°C (68°F) 

      If the result is not as specified, replace the No.2 cooling fan motor.

      Fig 2: Identifying No 2 Cooling Fan Motor Connector
      G04057777Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002