LEMON Manuals: Even more car manuals for everyone
Home >> Lexus >> 2006 >> IS 250 RWD, Standard >> Repair and Diagnosis >> External Pages >> Different car >> Section 12 (Automatic Transmission) >> Automatic Transmission System >> DTC P0778 Pressure Control Solenoid "B" Electrical (Shift Solenoid Valve SL2) >> Wiring Diagram

DTC P0778 Pressure Control Solenoid "B" Electrical (Shift Solenoid Valve SL2): Wiring Diagram

WARNING: This page is about a different car, the 2006 Lexus IS 350. However, it is still accessible from the selected car via links, so may be relevant.
Fig 1: Wiring Diagram - Pressure Control Solenoid "B" Electrical (Shift Solenoid Valve Sl2)
G04052898Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002

HINT:

  1. INSPECT TRANSMISSION WIRE (SL2) 
    1. Disconnect the transmission wire connector from the transmission.
    2. Measure the resistance according to the value(s) in the table below.

      Standard resistance 

      TESTER CONNECTION SPECIFIED CONDITION

      Tester Connection Specified Condition 20°C (68°F)
      10 (SL2+) - 2 (SL2-) 5.0 to 5.6 Ω
    3. Measure the resistance according to the value(s) in the table below.
      Fig 2: Inspecting Transmission Wire (Sl2)
      G04052899Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002

      Standard resistance (Check for short) 

      TESTER CONNECTION SPECIFIED CONDITION

      Tester Connection Specified Condition
      10 (SL2+) - Body ground 10 kΩ or higher
      2 (SL2-) - Body ground  

    NG : Go to step   3 

    OK : GO TO NEXT STEP 

  2. CHECK HARNESS AND CONNECTOR (TRANSMISSION WIRE - ECM) 
    1. Connect the transmission connector to the transmission.
    2. Disconnect the connector from the ECM.
    3. Measure the resistance according to the value(s) in the table below.
      Fig 3: Disconnecting E4 Connector From ECM
      G04052900Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002

      Standard resistance 

      TESTER CONNECTION SPECIFIED CONDITION

      Tester Connection Specified Condition 20°C (68°F)
      E4-11 (SL2+) - E4-10 (SL2-) 5.0 to 5.6 Ω
    4. Measure the resistance according to the value(s) in the table below.

      Standard resistance (Check for short) 

      TESTER CONNECTION SPECIFIED CONDITION

      Tester Connection Specified Condition
      E4-11 (SL2+) - Body ground 10 kΩ or higher
      E4-10 (SL2-) - Body ground  

    NG : REPAIR OR REPLACE HARNESS OR CONNECTOR 

    OK : REPLACE ECM 

  3. INSPECT SHIFT SOLENOID SL2 
    1. Remove the shift solenoid valve SL2.
    2. Measure the resistance according to the value(s) in the table below.

      Standard resistance 

      TESTER CONNECTION SPECIFIED CONDITION

      Tester Connection Specified Condition 20°C (68°F)
      1 - 2 5.0 to 5.6 Ω
    3. Connect the positive (+) lead with a 21 W bulb to terminal 2 and the negative (-) lead to terminal 1 of the solenoid valve connector, then check the movement of the valve.

      OK: The solenoid makes an operating sound. 

    NG : REPLACE SHIFT SOLENOID SL2 

    Fig 4: Inspecting Shift Solenoid Sl2
    G04052901Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002

    OK : REPAIR OR REPLACE TRANSMISSION WIRE