Typical Malfunction Thresholds

WARNING: This page is about a different car, the 2006 Lexus IS 350. However, it is still accessible from the selected car via links, so may be relevant.

[OFF malfunction]

Both of the following condition are met: OFF malfunctions (A) and (B)

OFF malfunction (A) 

TYPICAL ENABLING CONDITIONS

Turbine speed/Output speed (NT/NO) 0.93 or more, and 1.07 or less
(This means actual gear is 4th)

OFF malfunction (B) 

TYPICAL ENABLING CONDITIONS

Turbine speed/Output speed (NT/NO) 0.51 or more, and 0.65 or less
(This means actual gear is 6th)

[ON malfunction]

One of the following conditions is met: ON malfunctions (A), (B) and (C)

ON malfunction (A) 

TYPICAL ENABLING CONDITIONS

Turbine speed/Output speed (NT/NO) 1.28 or more, and 1.53 or less
(This means actual gear is 3rd)

ON malfunction (B) 

TYPICAL ENABLING CONDITIONS

Turbine speed - Output speed x 4th gear ratio (NT - NO x 4th gear ratio) 1,000 rpm or more

ON malfunction (C) 

TYPICAL ENABLING CONDITIONS

Turbine speed - Output speed x 5th gear ratio (NT - NO x 5th gear ratio) 1,000 rpm or more
  1. ACTIVE TEST 

    HINT:

    Performing the ACTIVE TEST using the intelligent tester allows the relay, VSV, actuator and so on to operate without parts removal. Performing the ACTIVE TEST as the first step of troubleshooting is one method to shorten labor time.

    It is possible to display the DATA LIST during the ACTIVE TEST.

    1. Warm up the engine.
    2. Turn the engine switch off.
    3. Connect the intelligent tester together with the CAN VIM (controller area network vehicle interface module) to the DLC3.
    4. Turn the engine switch on (IG) position.
    5. Turn on the tester.
    6. Select the item "DIAGNOSIS / ENHANCED OBD II / ACTIVE TEST / SHIFT".
    7. According to the display on the tester, perform the "ACTIVE TEST".

      HINT:

      While driving, the shift position can be forcibly changed with the intelligent tester.

      Comparing the shift position commanded by the ACTIVE TEST with the actual shift position enables you to confirm the problem (See DIAGNOSIS SYSTEM  ).

DATA LIST

Item Test Details Diagnostic Note
SHIFT [Test Details]
Operate the shift solenoid valve and set the each shift position by yourself.
[Vehicle Condition]
  • IDL: ON (4th, 5th and 6th)
  • Less than 50 km/h (31 mph)

[Others]
  • Press "-->" button: Shift up
  • Press "<--" button: Shift down
Possible to check the operation of the shift solenoid valves.

HINT:

  1. CHECK OTHER DTCS OUTPUT (IN ADDITION TO DTC P0761) 
    1. Connect the OBD II scan tool or the intelligent tester to the DLC3.
    2. Turn the engine switch on (IG) position and push the OBD II scan tool or the intelligent tester main switch ON.
    3. When you use intelligent tester:

      Select the item "DIAGNOSIS / ENHANCED OBD II / DTC INFO / CURRENT CODES".

    4. Read the DTCs using the intelligent tester.

      Result 

      DATA LIST

      Display (DTC output) Proceed to
      Only "P0761" is output A
      "P0761" and other DTCs B

      HINT:

      If any other codes besides "P0761" are output, perform troubleshooting for those DTCs first.

    B : GO TO  DTC CHART  

    A : GO TO NEXT STEP 

  2. PERFORM ACTIVE TEST BY INTELLIGENT TESTER (SHIFT SOLENOID VALVE SLT) 
    NOTE:
    • Perform the test at the normal operating ATF (Automatic Transmission Fluid) temperature: 50 to 80°C (122 to 176°F)
    • Be careful to prevent SST hose from interfering with the exhaust pipe.
    • This check must be conducted after checking and adjusting engine.
    • Perform under condition that A/C is OFF.

    HINT:

    Performing the ACTIVE TEST using the intelligent tester allows the relay, VSV, actuator and so on to operate without parts removal. Performing the ACTIVE TEST as the first step of troubleshooting is one method to shorten labor time. It is possible to display the DATA LIST during the ACTIVE TEST.

    1. Turn the engine switch off.
    2. Lift the vehicle up.
    3. Remove the test plug on the transmission case center right side and connect SST.

      SST 09992-00095 (09992-00231, 09992-00271) 

    4. Lower the vehicle.
    5. Fully apply the parking brake and chock the 4 wheels.
    6. Connect the intelligent tester together with the CAN VIM (controller area network vehicle interface module) to the DLC3.
    7. Start the engine.
    8. Warm up the ATF (Automatic Transmission Fluid).
    9. Measure the line pressure when the engine is idling.
    10. Turn on the tester.
    11. Select the item "DIAGNOSIS / ENHANCED OBD II / ACTIVE TEST / SOLENOID (SLT)".
    12. Follow the instructions on the tester and perform the ACTIVE TEST.
    13. Measure the line pressure with SST.
      Fig 1: Measuring Line Pressure With SST
      G04045746Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
      DATA LIST

      Item Test Details
      SOLENOID (SLT)(1) [Test Details]
      Operate the shift solenoid SLT and raise the line pressure.
      [Vehicle Condition]
      • Vehicle Stopped.
      • IDL: ON

      HINT:
      OFF: Line pressure up (When the active test of "SOLENOID (SLT)" is performed, the ECM commands the SLT solenoid to turn off).
      ON: No action (normal operation)
      (1) "SOLENOID (SLT)" in the ACTIVE TEST is performed to check the line pressure changes by connecting the SST to the automatic transmission, which is used in the HYDRAULIC TEST  as well.

      HINT:

      The pressure values in ACTIVE TEST and HYDRAULIC TEST are different from each other.

      OK: The line pressure changes as specified when performing the ACTIVE TEST. 

    NG : REPLACE SHIFT SOLENOID VALVE SLT 

    OK : GO TO NEXT STEP 

  3. INSPECT SHIFT SOLENOID VALVE S3 
    1. Remove the shift solenoid valve S3.
    2. Measure the resistance according to the value(s) in the table below.

      Standard resistance 

      TESTER CONNECTION SPECIFIED CONDITION

      Tester Connection Specified Condition 20°C (68°F)
      Solenoid Connector (S3) - Solenoid Body (S3) 11 to 15 Ω
    3. Connect the positive (+) lead to the terminal of the solenoid connector, and the negative (-) lead to the solenoid body.
      Fig 2: Inspecting Shift Solenoid Valve S3
      G04045750Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002

      OK: The solenoid makes an operating sound. 

    NG : REPLACE SHIFT SOLENOID VALVE S3 

    OK : GO TO NEXT STEP 

  4. INSPECT TRANSMISSION VALVE BODY ASSEMBLY 

    OK: There are no foreign objects on each valve. 

    NG : REPLACE TRANSMISSION VALVE BODY ASSEMBLY 

    OK : REPAIR OR REPLACE AUTOMATIC TRANSMISSION ASSEMBLY