Spiral Cable: Inspection
- INSPECT SPIRAL CABLE
- If there are any defects as mentioned below, replace the spiral cable with a new one:
Scratches, cracks, dents or chips on the connector or the spiral cable.
- Inspect the spiral cable.
- Measure the resistance according to the value(s) in the table below.
Standard resistance
TERMINALS RESISTANCE SPECIFICATIONTester connection Condition Specified condition k1-1- m1-2 Center Below 1 Ω 2.5 rotations to the left 2.5 rotations to the right k1-1- J24-8 (HO) Center Below 1 Ω 2.5 rotations to the left 2.5 rotations to the right k1-2- J24-9 (SUP) Center Below 1 Ω 2.5 rotations to the left 2.5 rotations to the right k1-3- J24-10 (SDN) Center Below 1 Ω 2.5 rotations to the left 2.5 rotations to the right k1-4- J24-11 (DIST) Center Below 1 Ω 2.5 rotations to the left 2.5 rotations to the right k1-5- J24-12 (IL+2) Center Below 1 Ω 2.5 rotations to the left 2.5 rotations to the right k1-6- m1-4 Center Below 1 Ω 2.5 rotations to the left 2.5 rotations to the right k1-6- J24-2 (ECC) Center Below 1 Ω 2.5 rotations to the left 2.5 rotations to the right k1-7- J24-3 (DISP) Center Below 1 Ω 2.5 rotations to the left 2.5 rotations to the right k1-8- J24-4 (EAU) Center Below 1 Ω 2.5 rotations to the left 2.5 rotations to the right k1-9- J24-5 (AU2) Center Below 1 Ω 2.5 rotations to the left 2.5 rotations to the right k1-10- J24-6 (AU1) Center Below 1 Ω 2.5 rotations to the left 2.5 rotations to the right m1-1- J24-7 (R/N) Center Below 1 Ω 2.5 rotations to the left 2.5 rotations to the right m1-2- J24-8 (HO) Center Below 1 Ω 2.5 rotations to the left 2.5 rotations to the right m1-3- J24-1 (CCS) Center Below 1 Ω 2.5 rotations to the left 2.5 rotations to the right m1-4- J24-2 (ECC) Center Below 1 Ω 2.5 rotations to the left 2.5 rotations to the right A-1 (D-) - J25-2 (D-) Center Below 1 Ω 2.5 rotations to the left 2.5 rotations to the right A-2 (D+) - J25-1 (D+) Center Below 1 Ω 2.5 rotations to the left 2.5 rotations to the right B-1 (D2-) - J25-3 (D2-) Center Below 1 Ω 2.5 rotations to the left 2.5 rotations to the right B-2 (D2+) - J25-4 (D2+) Center Below 1 Ω 2.5 rotations to the left 2.5 rotations to the right - If there are any defects as mentioned below, replace the spiral cable with a new one: