Fuel Lid Opener Motor Assembly: Inspection
- INSPECT FUEL LID OPENER MOTOR ASSEMBLY
- Apply battery voltage to the lock terminals and check that the motor operates and the shaft moves in the open direction.
OK
FUEL LID OPENER MOTOR ASSEMBLYMeasurement Condition Specified Condition Battery positive (+) --> Terminal 2
Battery negative (-) --> Terminal 1Motor operates and shaft moves in open direction - Measure the shaft stroke.
Standard: 10.3 mm (0.406 in.) or more
If the result is not as specified, replace the motor assembly.