Inspection Procedure
HINT:
- Start the inspection from step 1 when using the hand-held tester and start from step 3 when not using hand-held tester.
- The ECM sends information on the water temperature sensor to the meter through the BEAN. If there is on open or short circuit in the water temperature sensor circuit, the ECM outputs DTCs. Perform troubleshooting with the "Engine system" DIAGNOSTIC TROUBLE CODE CHART .
- PERFORM ACTIVE TEST BY HAND-HELD TESTER
- Operate the hand-held tester according to the steps on the display and perform the "ACTIVE TEST".
MTR (Combination meter):
ACTIVE TEST PERFORM BY HAND-HELD TESTER (MTR (COMBINATION METER))Item Test Details Diagnostic Note COOLANT TEMP LOW/NORM/HIGH -
- NG: REPLACE COMBINATION METER ASSY (See OVERHAUL )
- OK: Go to next step
- Operate the hand-held tester according to the steps on the display and perform the "ACTIVE TEST".
- READ VALUE OF HAND-HELD TESTER
- Operate the hand-held tester according to the steps on the display and select the "DATA LIST".
ALL (ECM):
VALUE OF HAND-HELD TESTER (ALL (ECM))Item Measurement Item/ Range (Display) Normal Condition Diagnostic Note COOLANT Coolant Temperature / Min.: -40 °C, Max.:140°C After warming up: 80 -95°C (176 - 203 °F) If the value is "-40 °C" or "140 °C", sensor circuit is open or shorted.
- NG: GO TO ENGINE CONTROL SYSTEM (See HOW TO PROCEED WITH TROUBLESHOOTING )
- OK: Go to next step
- Operate the hand-held tester according to the steps on the display and select the "DATA LIST".
- CHECK THAT MALFUNCTION DISAPPEARS A KNOWN GOOD COMBINATION METER IS INSTALLED
- NG: REPLACE ECM
- OK: REPLACE COMBINATION METER ASSY (See OVERHAUL )