Inspection Procedure
- INSPECT STOP LAMP SWITCH ASSY
- Check that the stop light lights up when brake pedal is depressed and turns OFF when the brake pedal is released.
NG : Go to step 4
OK : GO TO NEXT STEP
- INSPECT SKID CONTROL ECU TERMINAL VOLTAGE(STP TERMINAL)
- Remove the skid control ECU with connectors still connected.
- Measure voltage between terminal STP of skid control ECU and body ground when brake pedal is depressed.
OK:
Voltage: 8 - 14 V
OK : CHECK AND REPLACE SKID CONTROL ECU ASSY
NG : Go to next step
- CHECK HARNESS AND CONNECTOR(STOP LIGHT SWITCH - SKID CONTROL ECU)
- Check for open and short circuit in harness and connector between stop light switch and skid control ECU (See ELECTRONIC CIRCUIT INSPECTION PROCEDURE ).
NG : REPAIR OR REPLACE HARNESS OR CONNECTOR
OK : PROCEED TO NEXT CIRCUIT INSPECTION SHOWN ON PROBLEM SYMPTOMS TABLE )
- CHECK HARNESS AND CONNECTOR(STOP LIGHT CIRCUIT)
- Check for open and short circuit in harness and connector of the stop light circuit (See ELECTRONIC CIRCUIT INSPECTION PROCEDURE ).
OK : REPLACE STOP LAMP SWITCH ASSY
NG : REPAIR OR REPLACE HARNESS OR CONNECTOR