Inspection Procedure
HINT:
Start the inspection from step 1 in case of using the LEXUS hand-held tester and start from step 2 in case of not using the LEXUS hand-held tester.
- Check output value of the deceleration sensor.
PREPARATION:
- Connect the LEXUS hand-held tester to the DLC3.
- Turn the ignition switch ON, and push the LEXUS hand-held tester main switch ON.
- Select the DATALIST mode on the LEXUS hand-held tester.
CHECK:
Check that the deceleration value of the deceleration sensor displayed by the LEXUS hand-held tester is changing when tilting the vehicle.
OK:
Deceleration value must be changing.
- OK: Check and replace skid control ECU.
- NG: Go to next step.
- Check deceleration sensor (See PRE-CHECK
).
- NG: Replace deceleration sensor.
- OK: Go to next step.
- Check for open or short circuit in harness and connector between deceleration sensor and skid control ECU (See HOW TO USE THE DIAGNOSTIC CHART AND INSPECTION PROCEDURE
).
- NG: Repair or replace harness or connector.