Inspection Procedure
- CHECK COMBINATION METER ASSY
- Check voltage.
- Remove the combination meter assy with connectors still connected.
- Measure voltage between terminals C7-22 and C7-28 of combination meter assy.
Standard voltage: 5 V
- Measure voltage between terminals C7-8 and C7-22 of combination meter assy.
Standard voltage:
COMBINATION METER ASSY STANDARD VOLTAGEFuel level (Meter scale) Voltage (V) F 4.4 <==> 0.1 E 0.6 <==> 0.1 HINT:
As the fuel level is moved from F side to E side, the voltage decreases gradually without interruption.
- NG: CHECK AND REPLACE COMBINATION METER ASSY
- OK: Go to next step.
- Check voltage.
- INSPECT FUEL SENDER GAGE ASSY
- Check fuel sender gauge voltage.
- Remove the fuel sender gauge assy.
- Connect the positive (+) lead from the three 1.5 V dry cell batteries to terminal 2 (FV) and negative (-) lead to terminal 1 (FE).
- Measure voltage between terminals 1 (FE) and 3 (FR) of fuel sender gauge assy for each float position, as shown in the chart.
Standard voltage:
FUEL SENDER GAUGE ASSY STANDARD VOLTAGEFloat level Float position mm (in.) Voltage (V) F 73.4 (2.89) <==> 3 (0.12) 4.5 - 4.7 1/2 12.9 (0.51) <==> 3 (0.12) 2.2 - 2.6 E 51.3 (2.02) <==> 3 (0.12) 0.2 - 0.4
- NG: REPLACE FUEL SENDER GAGE ASSY
- OK: REPAIR OR REPLACE HARNESS OR CONNECTOR
- Check fuel sender gauge voltage.