Inspection Procedure
- INSPECT FUSE(GAUGE1, ECU-ACC)
- Check the continuity in GAUGE 1 fuse.
- Check the continuity in ECU-ACC fuse.
- NG: REPLACE FUSE
- OK: Go to next step.
- CHECK CLOCK ASSY
- Check voltage.
- Disconnect the connector from clock assy.
- Measure voltage between each terminals of clock assy and body ground at each condition as shown in the chart.
Standard:
CLOCK ASSY TERMINALS VOLTAGE CONDITIONTerminal Condition Voltage (V) 1 <==> Body ground Constant 10 - 14 4 <==> Body ground Ignition switch ACC 10 - 14 - Check continuity.
- Check the continuity in between terminal 2 of clock assy and body ground.
Standard: Continuity exists.
- Check the continuity in between terminal 2 of clock assy and body ground.
- OK: CHECK AND REPLACE CLOCK ASSY
- NG: REPAIR OR REPLACE HARNESS OR CONNECTOR
- Check voltage.