Inspection Procedure
- CHECK COMBINATION METER ASSY(TAU, TAUB, SPD)
- Disconnect the "C8" connector from combination meter assy.
- Check voltage (TAUB signal).
- Turn the ignition switch to ON.
- Measure the voltage between terminal C8-12 of combination meter assy connector and body ground.
Standard voltage: 10 - 14 V
- Check voltage (TAU signal).
- Turn the ignition switch to ON.
- Measure the voltage between terminal C8-21 of combination meter assy connector and body ground.
Standard voltage: 10 - 14 V
- Check signal waveform (TAU signal).
- B: GO TO FUEL SYSTEM
- C: CHECK AND REPLACE COMBINATION METER ASSY
- A: Go to next step.
- INSPECT FUSE(IGN)
- Check the continuity in IGN fuse.
- NG: REPLACE FUSE
- OK: REPAIR OR REPLACE HARNESS OR CONNECTOR