| C1233/33 |
When any of the following 1. through 4. is detected:
- ECU terminal IG1 voltage is 9.5 V to 17.0 V, and the condition that yaw rate sensor voltage is out of the range from 0.25 V to 4.75 V continued for 1 sec. or more.
- The conditions that yaw rate sensor open detect circuit signal is ON and the voltage of ECU terminal IG1 is 9.5 to 17 V continued for 1 sec. or more.
- The conditions that yaw rate sensor power source voltage is out of the range from 4.4 V to 5.6 V and the voltage of ECU terminal IG1 is 9.5 to 17 V continued for 1 sec. or more.
- When the condition that yaw rate sensor signal is momentarily open occurs 10 times or more and the voltage of ECU terminal IG1 is 9.5 to 17 V.
|
- Yaw rate sensor
- Yaw rate sensor circuit
|