Inspection Procedure
- DO ACTIVE TEST OF OBD II SCAN TOOL OR LEXUS HAND-HELD TESTER
- Check fuel receiver gauge operation.
- Connect the OBD II scan tool or LEXUS hand-held tester to DLC3.
- Turn the ignition switch ON and push the OBD II scan tool or LEXUS hand-held tester main switch ON.
- Select the ACTIVE TEST mode on the OBD II scan tool or LEXUS hand-held tester.
- Check that the prove moves as OBD II scan tool or LEXUS hand-held tester directs in each range.
OK: The meter operations normally.
- NG: CHECK AND REPLACE COMBINATION METER ASSY
- OK: GO TO NEXT STEP.
- Check fuel receiver gauge operation.
- INSPECT FUEL SENDER GAGE ASSY(MAIN)
- Check fuel sender gauge (main) resistance.
- Remove the fuel sender gauge.
- Measure resistance between terminals 2 and 3 of fuel sender gauge for each float position, as shown in the chart.
Standard resistance:
STANDARD RESISTANCE CHARTFloat Level Float position mm (in.) Resistance (Ω) F 34.6 (1.36) +/- 3 (0.12) 2.0 +/- 1 1/2 52.4 (2.06) +/- 3 (0.12) 26.1 +/- 3 E 134.9 (5.31) +/- 3 (0.12) 48.7 +/- 1 Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
- NG: REPLACE FUEL SENDER GAGE ASSY
- OK: GO TO NEXT STEP.
- Check fuel sender gauge (main) resistance.
- INSPECT FUEL SENDER GAGE ASSY (SUB)
- Check fuel sender gauge (sub) resistance.
- Remove the fuel sender gauge.
- Measure resistance between terminals of fuel sender gauge for each float position, as shown in the chart.
Standard resistance:
STANDARD RESISTANCE CHARTFloat Level Float position mm (in.) Resistance (Ω) F 9.5 (0.37) +/- 3 (0.12) 2.0 +/- 1 1/2 110.5(4.35) +/- 3 (0.12) 33.0 +/- 3 E 206.5 (8.13) +/- 3 (0.12) 61.3 +/- 1 - NG: REPLACE FUEL SENDER GAGE ASSY
- OK: GO TO NEXT STEP.
- Check fuel sender gauge (sub) resistance.
- CHECK WIRE HARNESS OR CONNECTOR(BETWEEN FUEL SENDER GAUGE I AND BODY GROUND)
- NG: REPAIR OR REPLACE WIRE HARNESS OR CONNECTOR
- OK: GO TO NEXT STEP.
- CHECK WIRE HARNESS OR CONNECTOR(BETEEN FUEL SENDER GAUGE AND I COMBINATION METER)
- NG: REPAIR OR REPLACE WIRE HARNESS OR CONNECTOR
- OK: CHECK AND REPLACE COMBINATION METER ASSY