Specific Fuel Consumption Gauge Circuit
NOTE:
If not using the hand-held tester, start the inspection from step 2.
- Connect the hand-held tester to the DLC3. See Figure. Turn the ignition switch ON and the hand-held tester main switch ON. Select the ACTIVE TEST mode on the hand-held tester. Check that the probe moves as the hand-held tester directs in each range. If the probe does not operate normally, go to the next step. If the probe operates normally, check the fuel sender gauge. See FUEL SENDER GAUGE under COMPONENT TESTS. If the results are OK, go to the next step. If the results are not good, replace the fuel sender gauge.
- Check the specific fuel consumption gauge. See SPECIFIC FUEL CONSUMPTION GAUGE under COMPONENT TESTS. If the results are OK, go to the next step. If the results are not good, replace the specific fuel consumption assembly. See COMBINATION METER CIRCUIT .
- Check the circuit plate. See COMBINATION METER CIRCUIT . If the results are OK, check and replace the combination meter. See COMBINATION METER under REMOVAL & INSTALLATION. If the results are not good, replace the circuit plate. See COMBINATION METER under REMOVAL & INSTALLATION.