No. 1, No. 2, No. 3 & No. 4 Solenoids
- To check solenoid seals, remove suspect solenoid. Connect battery voltage to solenoid. Apply 71 psi (5 kg/cm2 ) to solenoid with battery voltage connected.
- With battery voltage applied, air should pass through solenoid. Disconnect voltage to solenoid. Ensure air does not pass through solenoid. Replace solenoid if defective.
- Using ohmmeter, measure resistance between case and solenoid connector terminal. Resistance should be 11-15 ohms. Replace solenoid as necessary.