Cooling Fan Relays No. 1, 2 & 3: Es300
- Remove cooling fan relay from underhood relay block. Relays are marked FAN NO. 1, FAN NO. 2 and FAN NO. 3. On all relays, ensure continuity is present between relay terminals No. 1 and 2 (Nippondenso), or terminals No. 85 and 86 (Bosch). For relays No. 1 and 2, ensure there is continuity between relay terminals No. 3 and 4 (Nippondenso), or terminals No. 30 and 87a (Bosch). For relay No. 3, ensure there is no continuity between terminals No. 3 and 5. If continuity measurements are not to specification, replace cooling fan relay. If continuity measurements are to specification, go to next step.
- For relay No. 1, apply battery voltage and ground across relay terminals No. 1 and 2 (Nippondenso) or terminals No. 5 and 86 (Bosch). There should be no continuity between terminals No. 3 and 4 (Nippondenso) or terminals No. 30 and 87a (Bosch). Replace relay as necessary.
- For relay No. 2, apply battery voltage and ground across terminals No. 1 and 2. There should be no continuity between terminals No. 3 and 4, and continuity should exist between terminals No. 3 and 5. Replace relay as necessary.
- For relay No. 3, apply battery voltage and ground across terminals No. 1 and 2. There should be no continuity between terminals No. 3 and 5. Replace relay as necessary.