Positive Crankcase Ventilation System - Repair (G2956762): Removal
CAUTION:
Before disconnecting any components, make sure the area is clean and free from foreign material. When disconnected all openings must be sealed.
NOTE:
- This procedure contains some variation in the illustrations depending on the vehicle specification, but the essential information is always correct.
- This procedure contains illustrations showing certain components removed to provide extra clarity.
- Engine vent oil separator shown removed to provide extra clarity.
- Remove the engine cover.
Refer to: ENGINE COVER - INGENIUM I4 2.0L PETROL .
-
NOTE:
- Make sure only a suitable plastic tool is used.
- Note the orientation of the components.
- Only the diaphragm and the cap are to be discarded. The remaining components are to be reused.
- Remove the positive crankcase ventilation valve assembly.
- Discard the diaphragm.
- Discard the cap.