Auto Stop/Start System
The auto stop/start system is automatically enabled each time the ignition is switched to Power Mode 6 (ignition ON). The driver can disable the system using the auto stop/start switch soft key.
If the Remote Function Actuator (RFA) detects a valid smart key the driver will be able to start the engine.
For additional information, Refer to: ANTI-THEFT - PASSIVE
The BCM /GWM receives the hardwired crank request signal when:
- The ignition switch is operated with PARK (P) or NEUTRAL (N) selected on the TCS and the brake pedal is fully pressed (Vehicles with automatic transmission only).
Then the crank request signal is transmitted to the PCM . When the PCM receives the crank request signal, the PCM energizes the starter relay. The starter relay closed contacts causes a voltage to the motor solenoid, which energizes and transmits current into the motor brushes and armature. The armature rotational force is transferred to the drive plate ring gear through the pinion gear. This rotates the drive plate and starts the engine.
When the engine reaches self-sustaining operating speed, the PCM then de-energizes the starter relay to disconnect power from the starter motor. The purpose is to disengage the pinion gear from the drive plate ring gear.
The auto stop/start system is controlled by the PCM and the BCM /GWM through the FlexRay. Signals from other system components and modules are used to determine the correct conditions for system operation. The auto stop/start system detects when it is appropriate to stop and start the engine.
The auto stop/start system automatically stops the engine in appropriate conditions, resulting in 0 exhaust emissions and saving fuel when the vehicle is stationary. When the driver is ready to move off, the engine instantly restarts. Sophisticated controls make sure that the auto stop/start system does not compromise the needs of either the driver or the vehicle.
When the dynamic mode selected by the driver on the Interactive Control Display Module (ICDM), it will disables the auto stop/start system.
By default the stop/start system is enabled at the start of each ignition cycle. The auto stop/start system can be enabled/disabled using the auto stop/start soft key.
Auto Stop/Start Operation Conditions
Software within the PCM controls the operation of the auto stop/start system. In addition to its own dedicated components the auto stop/start system encompasses many other vehicle systems.
Complex technology interconnects these systems and makes sure that all the necessary conditions are satisfied by monitoring, among others:
- Brake hydraulic system pressure.
- Vehicle speed.
- The state of vital vehicle systems.
- Environmental conditions.
- TCS position (if equipped).
When all necessary conditions are satisfied, the auto stop/start system automatically stops the engine when:
- The vehicle stops from a speed higher than 17 km/h (10 mph).
- Sufficient pressure is applied to the brake pedal to make sure that the vehicle is stationary.
- The transmission is in DRIVE (D) or SPORT (S).
- PARK (P) or NEUTRAL (N) position is selected on the TCS .
The driver is notified that the engine has stopped by the auto stop/start warning indicator being illuminated in the IPC . Other warnings normally associated with an engine stop are not illuminated within an auto stop/start cycle.
When system conditions are not approved by the PCM the auto stop/start system does not behave as expected.
For example:
- System inhibit - The engine continues running even though the vehicle is stationary with the brake pedal pressed and the TCS in DRIVE (D) or SPORT (S). Another condition is when the vehicle is stationary and the TCS is in PARK (P) or NEUTRAL (N).
- System override - The engine has been stopped by the auto stop/start system but conditions have since changed, this activates an early automatic engine restart.
These interventions make sure the auto stop/start system does not impact on:
- Vehicle and occupant safety.
- Driver requirements.
- Occupant comfort.
The main control logic for auto stop/start operation resides in the PCM . However the BCM /GWM has software to communicate engine stoppage inhibits to the PCM . In some instances the driver is notified of the reason for the intervention. The displayed notifications are depending on the reason for the system intervention.
Stop Inhibitors
The following conditions prevent the auto stop/start system from stopping the engine.
Driver affected stop inhibitors:
- Driver disables the auto stop/start system.
- Gear selected on the paddle switch (if equipped).
- Reverse (R) is selected on the TCS (if equipped).
- The vehicle speed less than 17 km/h (10 mph) after reversing.
- The brake pedal is not fully pressed.
- The accelerator pedal is pressed.
- The vehicle is in dynamic mode.
- The hood is open.
- The driver door is open.
- The driver seatbelt is not fastened.
- Climate control system used above calibrated threshold.
- Windshield demist is operating.
- Trailer electrical connection detected.
Vehicle system affected stop inhibitors:
- Startup battery cold cranking capability below threshold.
- Startup battery State Of Charge (SOC) is low.
- Catalytic converter outside either pre or post calibration range.
- Engine coolant temperature below threshold.
- Engine oil temperature below threshold.
Environmental effected start initiators:
- Ambient air temperature rises above 40°C (104°F).
- Ambient air temperature falls below -5°C (23°F).
The maximum engine stop duration is 270 seconds, the vehicle starts after this time.
Start Inhibitors
When the engine stops within an auto stop/start cycle, certain conditions prevent an automatic restart.
Driver effected start inhibitors:
- The hood has been opened.
- The driver seatbelt is disengaged. (This is an automatic start inhibitor, therefore the engine can be restarted by releasing the brake pedal or operating the accelerator pedal.)
- The driver door is unlatched. (This is an automatic start inhibitor, therefore the engine can be restarted by releasing the brake pedal or operating the accelerator pedal.)
Vehicle system inhibitor:
- There is a system fault.