Heated Oxygen Sensor Live Data Signals
WARNING: This page is about a different variant/trim than selected.
| PID | DESCRIPTION | ACTION |
|---|---|---|
| BANK 1 | ||
| Live Data signal for Heated Oxygen Sensor - Pre catalyst - Bank 1 sensor 1 | ||
| 0x03A1 | Oxygen Sensor (O2S) Heater Duty Cycle Bank 1 Sensor 1 | Using the manufacturer approved diagnostic system check the live data signal. The signal is a duty cycle displayed in % varying between limits |
| 0xF434 | Oxygen Sensor Current Bank 1 sensor 1 | Using the manufacturer approved diagnostic system check the live data signal. The signal is displayed in mA varying between limits |
| Live Data signal for Heated Oxygen Sensor - Mid catalyst - Bank 1 sensor 2 | ||
| 0x03A2 | Oxygen Sensor (O2S) Heater Duty Cycle Bank 1 Sensor 2 | Using the manufacturer approved diagnostic system check the live data signal. The signal is a pulse width modulated signal digital output operating between 0 and 1 |
| 0xF415 | Oxygen Sensor Output Voltage Bank 1 - sensor 2 | Using the manufacturer approved diagnostic system check the live data signal. The signal is displayed in volts varying between limits |
| Live Data signal for Heated Oxygen Sensor - Post catalyst - Bank 1 sensor 3 | ||
| 0x03A3 | Oxygen sensor heater duty cycle - Bank 1 sensor 3 | Using the manufacturer approved diagnostic system check the live data signal. The signal is a pulse width modulated signal digital output operating between 0 and 1 |
| 0xF416 | Oxygen Sensor Output Voltage Bank 1 - sensor 3 | Using the manufacturer approved diagnostic system check the live data signal. The signal is displayed in volts varying between limits |