LEMON Manuals: Even more car manuals for everyone
Home >> Land Rover >> 2022 >> Defender 110 S >> Repair and Diagnosis >> External Pages >> Different variant/trim >> Section 4 (Electronic Engine Controls - INGENIUM I6 3.0L Petrol -- Defender/L663) >> Electronic Engine Controls - INGENIUM I6 3.0L Petrol >> Diagnosis And Testing >> Electronic Engine Controls - INGENIUM I6 3.0L Petrol (G3139674) >> Heated Oxygen Sensor Live Data Signals

Heated Oxygen Sensor Live Data Signals

WARNING: This page is about a different variant/trim than selected.
PID DESCRIPTION ACTION
BANK 1 
Live Data signal for Heated Oxygen Sensor - Pre catalyst - Bank 1 sensor 1 
0x03A1 Oxygen Sensor (O2S) Heater Duty Cycle Bank 1 Sensor 1 Using the manufacturer approved diagnostic system check the live data signal. The signal is a duty cycle displayed in % varying between limits
0xF434 Oxygen Sensor Current Bank 1 sensor 1 Using the manufacturer approved diagnostic system check the live data signal. The signal is displayed in mA varying between limits
Live Data signal for Heated Oxygen Sensor - Mid catalyst - Bank 1 sensor 2 
0x03A2 Oxygen Sensor (O2S) Heater Duty Cycle Bank 1 Sensor 2 Using the manufacturer approved diagnostic system check the live data signal. The signal is a pulse width modulated signal digital output operating between 0 and 1
0xF415 Oxygen Sensor Output Voltage Bank 1 - sensor 2 Using the manufacturer approved diagnostic system check the live data signal. The signal is displayed in volts varying between limits
Live Data signal for Heated Oxygen Sensor - Post catalyst - Bank 1 sensor 3 
0x03A3 Oxygen sensor heater duty cycle - Bank 1 sensor 3 Using the manufacturer approved diagnostic system check the live data signal. The signal is a pulse width modulated signal digital output operating between 0 and 1
0xF416 Oxygen Sensor Output Voltage Bank 1 - sensor 3 Using the manufacturer approved diagnostic system check the live data signal. The signal is displayed in volts varying between limits