Home >> Land Rover >> 2022 >> Defender 110 S >> Repair and Diagnosis >> External Pages >> Different variant/trim >> Section 18 (Battery, Mounting And Cables - Vehicles With: MHEV -- Defender/L663) >> Battery, Mounting And Cables - Vehicles With: MHEV >> Description And Operation >> Startup Battery And Cables - INGENIUM I6 3.0L Petrol (G2342547) >> Operation >> Electrical Load Management

Electrical Load Management

WARNING: This page is about a different variant/trim than selected.

The BCM  /GWM  contains the electrical load management. The BCM  /GWM  monitors the vehicle system power loads in all Power Modes.

Engine Stop/Start Operation with The Starter Motor 

For additional information, Refer to: QUIESCENT DRAIN

When the engine is stopped, the BCM  /GWM  continues to monitor the startup battery State of Charge. When the startup battery voltage is less than 11.2V, the BCM  /GWM  initiates an engine start. A startup battery voltage of less than 11.2V, results in degraded starting performance or possible startup battery damage.