LEMON Manuals: Even more car manuals for everyone
Home >> Land Rover >> 2021 >> Range Rover Velar R-Dynamic HSE >> Repair and Diagnosis >> External Pages >> Different variant/trim >> Section 8 (Engine Cooling - INGENIUM I4 2.0L PETROLL/INGENIUM I4 2.0L Petrol PHEV -- Range Rover Velar/L560) >> Engine Cooling - INGENIUM I4 2.0L Petrol/INGENIUM I4 2.0L Petrol - PHEV >> Description And Operation >> Engine Cooling - Vehicles With: PHEV (G2856524) >> Description >> Electric Cooling Fan

Electric Cooling Fan

WARNING: This page is about a different variant/trim than selected.
G14285965Courtesy of JAGUAR LAND ROVER NORTH AMERICA, LLC
ITEM DESCRIPTION
1 Electric cooling fan shroud
2 Electric cooling fan blade
3 Electrical connector
4 Electric cooling fan motor
5 Speed flap (8 off)

The electric, variable speed cooling fan is installed in a shroud attached to the rear of the radiator. The electric cooling fan is operated by the engine cooling fan control module, which is integrated into the electric cooling fan motor. The PCM  controls the engine cooling fan control module through a PWM  signal. An electrical connector at the right side of the shroud provides the interface between the electric cooling fan harness and the vehicle wiring.

The engine cooling fan control module is provided with:

The system is protected against abnormal internal temperature by measuring its internal temperature at two points with temperature sensors:

The electric cooling fan will derate if the powerstage internal temperature reaches 135°C (275°F) and stop motor function at 145°C (293°F). At motor stop, after a delay of 120 seconds the diagnostic feedback will be sent. Normal electric cooling fan operation will resume when the powerstage temperature falls to 135°C (275°F).